Industrial Trials of a Modernized Separation Part of Moisture Separators-Reheaters at the Leningrad and Smolensk NPP


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The purpose of this work is to compare industrial trials of modernized intermediate SPP-500-1 moisture separators-heaters of the K-500-65/3000 turbines in the No. 4 unit of the Leningrad NPP and the No. 1 unit of the Smolensk NPP. It was found that the distribution of the separated moisture along the perimeter and height of the steam space at the egress from the separation units is uniform in both NPP. A very small increase of the moisture concentration at the wall was obtained in individual apparatus at the Smolensk (No. 24) and Leningrad (No. 72) NPP. The flow rate of the separated material and the condensate of the warming steam, as measured on the Nos. 1 and 2 turbines of the Smolensk NPP, is close to that obtained on the Nos. 7 and 8 turbines of the Leningrad NPP. In the course of the industrial trials, it was shown experimentally that the moisture and flow rate are the same. This confirms the reliability of the results, which after modernization are close to the design-basis level.

作者简介

M. Egorov

St. Petersburg Polytechnic University

编辑信件的主要联系方式.
Email: mikhail.yu.egorov@gmail.com
俄罗斯联邦, St. Petersburg

补充文件

附件文件
动作
1. JATS XML

版权所有 © Springer Science+Business Media, LLC, part of Springer Nature, 2019