A method of calculating fission product transport in the first loop of VVER is proposed. In this method the coefficients of mass transfer are calculated using the CONTOUR hydraulic code. Computational results are reported for a problem where the transport of fission products in a reactor loop with partially damaged fuel elements is modeled.