Magnetostriction electromagnetic–acoustic excitation of ultrasonic waves without a bias field
- 作者: Gobov Y.L.1, Mikhailov A.V.1,2, Smorodinskii Y.G.1,2
-
隶属关系:
- Mikheev Institute of Physics of Metals, Ural Branch
- Ural Federal University
- 期: 卷 52, 编号 12 (2016)
- 页面: 697-702
- 栏目: Acoustic Methods
- URL: https://journals.rcsi.science/1061-8309/article/view/181234
- DOI: https://doi.org/10.1134/S106183091612007X
- ID: 181234
如何引用文章
详细
A high-performance technique is suggested for generating ultrasonic waves by the magnetic–acoustic method without using a bias field. The technique is based on the frequency doubling of emitted ultrasonic wave as compared to the frequency of the field coil of electromagnetic transducer due to the evenness of magnetostriction. The efficiency of excitation and reception of ultrasonic waves at the doubled frequency without a bias field is compared with that at the base frequency with a bias field.
作者简介
Yu. Gobov
Mikheev Institute of Physics of Metals, Ural Branch
编辑信件的主要联系方式.
Email: go@imp.uran.ru
俄罗斯联邦, Yekaterinburg, 620990
A. Mikhailov
Mikheev Institute of Physics of Metals, Ural Branch; Ural Federal University
Email: go@imp.uran.ru
俄罗斯联邦, Yekaterinburg, 620990; Yekaterinburg, 620002
Ya. Smorodinskii
Mikheev Institute of Physics of Metals, Ural Branch; Ural Federal University
Email: go@imp.uran.ru
俄罗斯联邦, Yekaterinburg, 620990; Yekaterinburg, 620002
补充文件