A correction factor for the amplitude adjustment for the pulse echo ultrasonic inspection of components with curved surfaces


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

On the basis of analyzed factors that lead to the amplitude variation of an echo signal from identical reflectors in a quality-control sample and a test sample with curved surfaces, the correction factor for the amplitude adjustment is represented as the product of several factors. Calculation methods are proposed for the components of the correction factor for the case of a curved entry surface of an arbitrary shape and a position relative to the transducer.

作者简介

A. Michurov

OOO Rubezh

编辑信件的主要联系方式.
Email: michurovav@yandex.ru
俄罗斯联邦, Megion

A. Sokolkin

OOO Rubezh

Email: michurovav@yandex.ru
俄罗斯联邦, Megion