A Betatron Tomograph for Nondestructive Testing of Products with a Diameter up to 1000 mm Made of High-Energy Materials


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Results of developing and testing a betatron-based tomograph with an energy of up to 10 MeV are presented. The tomograph allows investigating objects with a shined-though thickness of up to 250 mm in steel equivalent. In contrast to foreign analogs, a horizontal product arrangement is used; it creates the most favorable conditions for revealing such defects as cracks and delaminations, since in this position, the product is subjected to small deformations due to gravitational forces. The proposed scanning scheme has the properties of a third-generation tomograph and preserves the quality of the tomogram and the time it is gathered with a reduced number of detectors and tomograph dimensions. The results of evaluating the tomograph sensitivity with a test sample and the results of testing products containing defects are provided.

作者简介

V. Karikh

Federal Research and Production Center “Altai”

编辑信件的主要联系方式.
Email: kar@frps.secna.ru
俄罗斯联邦, Biisk, Altai Krai, 659322

A. Kodolov

Federal Research and Production Center “Altai”

Email: kar@frps.secna.ru
俄罗斯联邦, Biisk, Altai Krai, 659322

A. Okhotnikov

Federal Research and Production Center “Altai”

Email: kar@frps.secna.ru
俄罗斯联邦, Biisk, Altai Krai, 659322

A. Skokov

Federal Research and Production Center “Altai”

Email: kar@frps.secna.ru
俄罗斯联邦, Biisk, Altai Krai, 659322

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2019