Studying a Signal due to the Tangential Component of Stray Fluxes from a Surface Flaw Detected with a Vibrating Induction Transducer
- Авторы: Nikolaev Y.1, Shkatov P.1, Chernova A.1
-
Учреждения:
- Moscow Technological University (MIREA)
- Выпуск: Том 54, № 5 (2018)
- Страницы: 372-376
- Раздел: Electromagnetic Methods
- URL: https://journals.rcsi.science/1061-8309/article/view/181669
- DOI: https://doi.org/10.1134/S1061830918050108
- ID: 181669
Цитировать
Аннотация
Analytical dependences of the amplitude spectrum of the output signal of a vibrating induction transducer on its position with respect to a flaw and on vibration-displacement parameters have been derived. The locality of inspection and its selective sensitivity toward flaws have been evaluated. The results of theoretical research have been confirmed experimentally.