Comparing the Efficiency of Ultrasonic Infrared Thermography under High-Power and Resonant Stimulation of Impact Damage in a CFRP Composite


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The quality control of composite materials remains an important topic of research in nondestructive testing (NDT) of modern materials, in particular, the ones intended for aerospace industry. Over the last decade, there has been a noticeable increase in interest to the ultrasonic stimulation of tested materials and analysis of dynamic temperature distributions. This method is commonly implemented with two techniques, viz. high-power stimulation at a fixed acoustic-signal frequency and low-power resonant ultrasonic stimulation. Results are provided on comparing the above ultrasonic NDT methods using the example of an impact damage in a graphite epoxy-filled composite. The comparison is made based on the criteria of temperature signals, revealed flawed zone, and productivity of testing.

作者简介

D. Derusova

Tomsk Polytechnic University; Institute of Strength Physics and Materials Science, Siberian Branch

编辑信件的主要联系方式.
Email: red@tpu.ru
俄罗斯联邦, Tomsk, 634028; Tomsk, 634050

V. Vavilov

Tomsk Polytechnic University

Email: red@tpu.ru
俄罗斯联邦, Tomsk, 634028

Xingwang Guo

Beijing University of Aeronautics and Astronautics

Email: red@tpu.ru
中国, Beijing, 100191

N.V. Druzhinin

Institute of Strength Physics and Materials Science, Siberian Branch

Email: red@tpu.ru
俄罗斯联邦, Tomsk, 634050

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2018