Peculiarities of Changes in the Desired Signal of a Magnetic Anisometer under Rotation of Its Attachable Sensor
- Authors: Zakharov V.A.1, Molin S.M.1, Len’kov S.V.1, Kolyasev V.A.1
-
Affiliations:
- Physical-Technical Institute, Ural Branch
- Issue: Vol 54, No 1 (2018)
- Pages: 65-69
- Section: Electromagnetic Methods
- URL: https://journals.rcsi.science/1061-8309/article/view/181530
- DOI: https://doi.org/10.1134/S1061830918010102
- ID: 181530
Cite item
Abstract
The way the rotation and speed of the sensor in a permanent-magnet anisometer affect its readings when inspecting the stress-strained state of ferromagnetic articles has been studied. Regularities of changes in the longitudinal and transverse magnetic-field strength components during sensor rotation have been revealed. A degree to which both components depend on the rotation speed has been demonstrated.
About the authors
V. A. Zakharov
Physical-Technical Institute, Ural Branch
Author for correspondence.
Email: zva@ftiudm.ru
Russian Federation, Izhevsk, 426000
S. M. Molin
Physical-Technical Institute, Ural Branch
Email: zva@ftiudm.ru
Russian Federation, Izhevsk, 426000
S. V. Len’kov
Physical-Technical Institute, Ural Branch
Email: zva@ftiudm.ru
Russian Federation, Izhevsk, 426000
V. A. Kolyasev
Physical-Technical Institute, Ural Branch
Email: zva@ftiudm.ru
Russian Federation, Izhevsk, 426000