LOCAL AND SYSTEMIC INFLAMMATORY REACTIONS AFTER IMPLANTATION OF DIFFERENT COMPOSITION SMALL DIAMETER VASCULAR GRAFTS

封面

如何引用文章

全文:

详细

The most important criterion of implantable vascular prostheses biocompatibility is the intensity of local and systemic inflammatory reactions to the graft material. Purpose: To evaluate the intensity of local and systemic inflammatory reactions of the organism in the acute period after implantation of small diameter vascular prostheses created on the basis of different biodegradable polymers. Obtained by electrospinning biopolymer prosthesis were implanted in the abdominal aorta of rats: I - polycaprolactone (PCL); II - copolymer of polylactic acid/polycaprolactone (PLC 7015); III - copolymer of polylactic acid/ polycaprolactone with polyglycolide (PLC 7015-PGS); IV - polylactic acid/polycaprolactone (PL-18PCL); V - polycapro-lactone/polyglycolide (PCL-PGS); VI - sham-operated control group. Grafts explantation was performed on the 14th day. The intensity of the systemic inflammatory response was assessed by serum level of IL-6, IL-10 and MCP-1, the intensity of the local inflammatory reaction - by HE-stained grafts sections analyzing. Prosthesis implantation in all cases was accompanied by the local inflammatory reaction development that was most pronounced in the case of PL-18PCL and PCL-PGS. Elevated level of MCP-1 was observed only by PLC 7015 grafts implantation. All studied polymers could be used as a stock for small diameter vascular prostheses development.

作者简介

A. Mishanin

Federal Almazov Nord-West Medical Research Centre

编辑信件的主要联系方式.
Email: noemail@neicon.ru
俄罗斯联邦

V. Vavilov

Saint Petersburg Pavlov State Medical University

Email: noemail@neicon.ru
俄罗斯联邦

S. Tverdokhlebov

Tomsk National Polytechnic University

Email: noemail@neicon.ru
俄罗斯联邦

E. Bolbasov

Tomsk National Polytechnic University

Email: noemail@neicon.ru
俄罗斯联邦

A. Golovkin

Federal Almazov Nord-West Medical Research Centre

Email: noemail@neicon.ru
俄罗斯联邦

参考

  1. Li C et al. Comprehensive mechanical characterization of PLA fabric combined with PCL to form a composite structure vascular graft. J Mech Behav Biomed Mater. 2017 May, 69, 39-49.
  2. Yin A et al. Coaxial electrospinning multicomponent functional controlled-release vascular graft: Optimization of graft properties. Colloids Surf B Biointerfaces. 2017 Apr 1, 152, 432-439.
  3. Williams DF. There is no such thing as a biocompatible New Biodegradable Vascular Graft via In Vitro Comaterial. Biomaterials. 2014, 35(38), 10009-10014. culture Approaches and In Vivo Model. Ann Biomed
  4. Enayati M et al. Biocompatibility Assessment of a Eng. 2016 Nov, 44(11), 3319-3334.

版权所有 © Mishanin A.I., Vavilov V.N., Tverdokhlebov S.I., Bolbasov E.N., Golovkin A.S., 2017

Creative Commons License
此作品已接受知识共享署名 4.0国际许可协议的许可
##common.cookie##