Metrological Control of the Spatial Positions of Elements of the Millimetron Telescope Primary Mirror
- Autores: Sychev V.V.1, Klem A.I.1,2
-
Afiliações:
- Bauman Moscow State Technical University
- Astro Space Center, Lebedev Physical Institute
- Edição: Volume 31, Nº 6 (2018)
- Páginas: 727-732
- Seção: Adaptive and Integral Optics
- URL: https://journals.rcsi.science/1024-8560/article/view/188640
- DOI: https://doi.org/10.1134/S1024856018060167
- ID: 188640
Citar
Resumo
Possible versions of sensors based on the pseudoreversal of the wavefront of the measuring beam and photoelectronic–optical amplification of the angular misalignment signal are considered. Estimation of the sensor parameters suggests the possibility of creating measuring systems that meet the requirements of the Millimetron telescope.
Sobre autores
V. Sychev
Bauman Moscow State Technical University
Autor responsável pela correspondência
Email: viktorsychev@list.ru
Rússia, Moscow, 107005
A. Klem
Bauman Moscow State Technical University; Astro Space Center, Lebedev Physical Institute
Email: viktorsychev@list.ru
Rússia, Moscow, 107005; Moscow, 119991
Arquivos suplementares