Expert Module of the Thermal Probes System for Blast Furnace Charging Control


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

For blast furnaces equipped with bell-less and bell-type charging systems, the optimal ranges of the characteristics K1K4 of the gas-flux distribution are established for different gas-dynamic conditions and different fuels. An expert module has been developed for the system monitoring the temperature of the gas flux above the batch surface in controlling the charge at two blast furnaces. Tests of the module prove successful.

About the authors

Yu. S. Semenov

Z.I. Nekrasov Iron and Steel Institute (ISI), National Academy of Sciences of Ukraine; ISD Scientific Technical Company

Author for correspondence.
Email: yuriy.semenov.isi@gmail.com
Ukraine, Dnipro; Dnipro

E. I. Shumelchik

Z.I. Nekrasov Iron and Steel Institute (ISI), National Academy of Sciences of Ukraine; ISD Scientific Technical Company

Email: yuriy.semenov.isi@gmail.com
Ukraine, Dnipro; Dnipro

V. V. Horupakha

Z.I. Nekrasov Iron and Steel Institute (ISI), National Academy of Sciences of Ukraine; ISD Scientific Technical Company

Email: yuriy.semenov.isi@gmail.com
Ukraine, Dnipro; Dnipro