Development of a Microfluidic NMR Device for Rapid and Quantitative Detection of Tumor Markers
- Authors: Lu R.1,2, Lei P.1,2, Yang Q.1,2, Ni Z.1,2, Yi H.1,2
-
Affiliations:
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University
- School of Mechanical Engineering, Southeast University
- Issue: Vol 50, No 1-3 (2019)
- Pages: 357-370
- Section: Original Paper
- URL: https://journals.rcsi.science/0937-9347/article/view/248261
- DOI: https://doi.org/10.1007/s00723-018-1071-5
- ID: 248261
Cite item
Abstract
In this work, a low-field microfluidic nuclear magnetic resonance (NMR) detection device was developed by fabricating a multi-layer microfluidic NMR probe. In combination with biological sensor technology based on immunomagnetic nanoparticles (IMNPs), the microfluidic NMR detection device was used to rapidly distinguish the concentration of target tumor markers. The experimental results show that the concentration of the target tumor markers can be differentiated with high sensitivity and specificity by the rate of the transverse relaxation time change ΔT2 even with interference from other biomarkers. A good linear relationship between ΔT2 and the concentration of the target tumor markers was also found, indicating that the microfluidic NMR device could be used for quantitative detection of tumor markers. Finally, the validity of the microfluidic NMR device for detecting target tumor markers was proved by comparison with a commercial cell counter, and the results detected by the two devices have a good consistency with a correlation coefficient of 0.996. In conclusion, the presented low-field microfluidic NMR device is a potential tool for the rapid and accurate quantitative detection of tumor markers.
About the authors
Rongsheng Lu
Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University; School of Mechanical Engineering, Southeast University
Author for correspondence.
Email: lurs@seu.edu.cn
China, Nanjing, 211189; Nanjing, 211189
Pengkun Lei
Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University; School of Mechanical Engineering, Southeast University
Email: yihong@seu.edu.cn
China, Nanjing, 211189; Nanjing, 211189
Qing Yang
Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University; School of Mechanical Engineering, Southeast University
Email: yihong@seu.edu.cn
China, Nanjing, 211189; Nanjing, 211189
Zhonghua Ni
Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University; School of Mechanical Engineering, Southeast University
Email: yihong@seu.edu.cn
China, Nanjing, 211189; Nanjing, 211189
Hong Yi
Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University; School of Mechanical Engineering, Southeast University
Author for correspondence.
Email: yihong@seu.edu.cn
China, Nanjing, 211189; Nanjing, 211189
Supplementary files