Multiple Parallel Round Leg Design for Quadrature Birdcage Coil in Ultrahigh-Field MRI


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

Copper foil has been widely employed in conventional radio frequency (RF) birdcage coils for magnetic resonance imaging (MRI). However, for ultrahigh-field (UHF) MRI, current density distribution on the copper foil is concentrated on the surface and the edge due to proximity effect. This increases the effective resistance and distorts the circumferential sinusoidal current distribution on the birdcage coils, resulting in low signal-to-noise ratio (SNR) and inhomogeneous distribution of RF magnetic (B1) field. In this context, multiple parallel round wires were proposed as legs of a birdcage coil to optimize current density distribution and to improve the SNR and the B1 field homogeneity. The design was compared with three conventional birdcage coils with different width flat strip surface legs for a 9.4 T (T) MRI system, e.g., narrow-leg birdcage coil (NL), medium-leg birdcage coil (ML), broad-leg birdcage coil (BL) and the multiple parallel round wire-leg birdcage coil (WL). Studies were carried out in in vitro saline phantom as well as in vivo mouse brain. WL showed higher coil quality factor Q and more homogeneous B1 field distribution compared to the other three conventional birdcage coils. Furthermore, WL showed 12, 10 and 13% SNR increase, respectively, compared to NL, ML and BL. It was proposed that conductor’s shape optimization could be an effective approach to improve RF coil performance for UHF MRI.

About the authors

Yongfeng Xu

High Magnetic Field Laboratory, Chinese Academy of Sciences; University of Science and Technology of China

Email: kzhong@hmfl.ac.cn
China, Hefei, 230031; Hefei, 230026

Qingqing Wen

High Magnetic Field Laboratory, Chinese Academy of Sciences; University of Chinese Academy of Sciences

Email: kzhong@hmfl.ac.cn
China, Hefei, 230031; Beijing, 10010

Hongyi Yang

High Magnetic Field Laboratory, Chinese Academy of Sciences

Email: kzhong@hmfl.ac.cn
China, Hefei, 230031

Kai Zhong

High Magnetic Field Laboratory, Chinese Academy of Sciences; CAS Center for Excellence in Brain Science and Intelligence Technology, Chinese Academy of Sciences; University of Science and Technology of China

Author for correspondence.
Email: kzhong@hmfl.ac.cn
China, Hefei, 230031; Hefei; Hefei, 230026


Copyright (c) 2017 Springer-Verlag GmbH Austria, part of Springer Nature

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies