Early and Mid-Term Results of Primary Hip Arthroplasty Using Il’za Endoprosthesis


Cite item

Full Text

Abstract

The problems of hip arthroplasty under conditions of wide introduction of that surgical intervention into clinical practice and the perspectives of cementless wedge-shaped femoral stems use are discussed on the example of high-technology home endoprosthesis “Il’za” are discussed. Technical characteristics of the implant, peculiarities of surgical procedure with its application, early and mid-term clinical and roentgenologic results of 581 operations are considered. Stable deterioration of hip function has been noted in 1, 2 and 3 years after operation - from 37.6 points by Harris hip score to 89.3, 92.2, and 89.1 points, respectively. Survival of the femoral component in 6 years after arthroplasty made up 98.6%, general survival - 96.2%. Universality of this femoral component that enables to achieve its stable primary and secondary fixation in the absolute majority of patients is proved. The achieved data allow to talk of the reliability of wedge-shaped femoral hip stems and significant prospective for their use in wide clinical practice.

About the authors

S. P Mironov

Central Institute of Traumatology and Orthopaedics named after N.N. Priorov

академик РАН и РАМН, профессор, директор ЦИТО

A. V Balberkin

Central Institute of Traumatology and Orthopaedics named after N.N. Priorov

доктор мед. наук, зав. отделением костной патологии взрослых ЦИТО

N. V Zagorodniy

Central Institute of Traumatology and Orthopaedics named after N.N. Priorov

доктор мед. наук, профессор, зав. отделением эндопротезирования ЦИТО

V. N Karpov

MATI Russian State Technological University, Moscow, Russia

доктор мед. наук, профессор кафедры материаловедения и технологии обработки материалов МАТИ - РГТУ

A. F Kolondaev

Central Institute of Traumatology and Orthopaedics named after N.N. Priorov

Email: klnd@inbox.ru
канд. мед. наук, врач отделения костной патологии взрослых ЦИТО; Тел.: 8 (495) 450-37-49 127299, Москва, ул. Приорова, д. 10, ЦИТО

D. A Shavyrin

Central Institute of Traumatology and Orthopaedics named after N.N. Priorov

доктор мед. наук, врач отделения костной патологии взрослых ЦИТО

D. A Snetkov

Central Institute of Traumatology and Orthopaedics named after N.N. Priorov

канд. мед. наук, врач отделения костной патологии взрослых ЦИТО

References

  1. Андреева Т.М., Огрызко Е.В., Попова М.М. Травматизм, ортопедическая заболеваемость, состояние травматолого-ортопедической помощи населению России в 2013 году: Сборник. Под ред. С.П. Миронова. М.; 2014.
  2. Allen Butler R., Rosenzweig S., Myers L., Barrack R.L. The Frank Stinchfield Award: the impact of socioeconomic factors on outcome after THA: a prospective, randomized study. Clin. Orthop. Relat. Res. 2011; 469 (2): 339-47.
  3. Pedersen A.B., Baron J.A., Overgaard S., Johnsen S.P. Short- and long-term mortality following primary total hip replacement for osteoarthritis: a Danish nationwide epidemiological study. J. Bone Joint Surg. Br. 2011; 93 (2): 172-7.
  4. Pitto R.P., Lang I., Kienapfel H., Willert H-G. The German Arthroplasty Register. Acta Orthop. Scand. (Suppl 305). 2002; 73: 30-3.
  5. Soohoo N.F., Farng E., Lieberman J.R., Chambers L., Zingmond D.S. Factors that predict short-term complication rates after total hip arthroplasty. Clin. Orthop. Relat. Res. 2010; 468 (9): 2363-71.
  6. The Swedish hip arthroplasty register. Annual report 2005. Department of Orthopaedics Sahlgrenska University Hospital. August 2006.
  7. Mahomed N.N., Barrett J.A., Katz J.N., Phillips C.B., Losina E., Lew R.A. et al. Rates and outcomes of primary and revision total hip replacement in the United States Medicare population. J. Bone Joint Surg. Am. 2003; 85 (1): 27-32.
  8. Дустов Х.С. Результаты клинического применения отечественного эндопротеза «Ильза» при лечении больных с заболеваниями и повреждениями тазобедренного сустава. Дис. … канд. мед. наук. М.; 2013.
  9. Fousek J., Indrakova P. Total hip arthroplasty in post-dysplastic hip arthritis. Can type and position of the acetabular component influence longevity of the prosthesis? Acta Chir. Orthop. Traumatol. Cech. 2007; 74: 47-54 [Article in Czech].
  10. Hopley C., Stengel D., Ekkernkamp A., Wich M. Primary total hip arthroplasty versus hemiarthroplasty for displaced intracapsular hip fractures in older patients: systematic review. BMJ. 2010; 340 (c2332): 1-14.
  11. Harris W.H. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation, J. Bone Joint Surg. Am. 1969; 51 (4): 737-55.
  12. Елкин Д.В. Клинико-анатомическое обоснование применения бедренных компонентов дистальной фиксации при эндопротезировании тазобедренного сустава: Дис. …канд. мед. наук. М.; 2008.
  13. Загородний Н.В. Эндопротезирование при повреждениях и заболеваниях тазобедренного сустава: Дис. … д-ра мед. наук. М.; 1998.
  14. Brady O.H., Kerry R., Masri B.A., Garbus D.S., Duncan K.P. The Vancouver classification of periprosthetic fractures of the hip: a rational approach to treatment. Techn. Orthop. 1999; 14: 107-14.
  15. Mueller L.A., Nowak T.E., Haeberle L., Mueller L.P., Kress A., Voelk M. et al. Progressive femoral cortical and cancellous bone density loss after uncemented tapered-design stem fixation. Acta Orthop. 2010; 81 (2): 171-7.
  16. Bourne R.B., Corten K. Cemented versus cementless stems: a verdict is in. Orthopedics. 2010; 33 (9): 638.
  17. Carl H.D., Ploetzner J., Swoboda B., Weseloh G., Mueller L.A. Cementless total hip arthroplasty in patients with rheumatoid arthritis using a tapered designed titanium hip stem minimum: 10-year results. Rheumatol. Int. 2011; 31 (3): 353-9.
  18. Corten K., Bourne R.B., Charron K.D., Au K., Rorabeck C.H. What works best, a cemented or cementless primary total hip arthroplasty?: minimum 17-year followup of a randomized controlled trial. Clin. Orthop. Relat. Res. 2011; 469 (1): 209-17.
  19. Kim Y.H., Choi Y., Kim J.S. Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis. Int. Orthop. 2010; 34 (8): 1123-7.
  20. Kress A.M., Schmidt R., Holzwarth U., Forst R., Mueller L.A. Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up. Int. Orthop. 2011; 35 (2): 195-200.
  21. McLaughlin J.R., Lee K.R. Uncemented total hip arthroplasty with a tapered femoral component: a 22- to 26-year follow-up study. Orthopedics. 2010; 33 (9): 639.
  22. Yamada H., Yoshihara Y., Henmi O. Cementless total hip replacement: past, present, and future. J. Orthop. Sci. 2009; 14: 228-41.
  23. Ильин А.А., Загородний Н.В., Мамонов А.М., Балберкин А.А., Карпов В.Н., Макунин В.И. и др. Обоснование конструкции и исследование биомеханического поведения клиновидной ножки цементной фиксации эндопротезов тазобедренного сустава. Вестник травматологии и ортопедии им. Н.Н. Приорова. 2005; 3: 3-10.
  24. Палтиевич А.Р., Поляков О.А., Курников Д.А. и др. Компьютерное моделирование ротационной стабильности бедренных компонентов эндопротезов тазобедренного сустава. В кн.: Тезисы докладов Всероссийской научно-технической конференции «Новые материалы и технологии», НМТ-2004. М.: ЛАТМЭС; 2004: 81-2.
  25. Ильин А.А., Мамонов А.М., Скворцова С.В. и др. Некоторые инновационные технологии в производстве медицинских имплантатов из титановых сплавов. Технология легких сплавов. 2007; 3: 131-7.
  26. Ильин А.А., Скворцова С.В., Лукина Е.А., Карпов В.Н., Поляков О.А. Низкотемпературное ионное азотирование имплантатов из титанового сплава ВТ20 в различных структурных состояниях. Металлы. 2005; 2: 38-45.
  27. Поляков О.А. Влияние технологических факторов на структуру и механические свойства компонентов эндопротезов из титанового сплава ВТ20: Дис. … канд. техн. наук. М.; 2007.
  28. Thomson A., Lee A.J. Torsional stability of a polished, collarless, tapered total replacement hip joint stem under vertical load: an in vitro investigation. Proc. Inst. Mech. Eng. H. 2011; 225 (1): 77-85.
  29. Dalury D.F., Gonzales R.A., Adams M.J. Minimum 5-year results in 96 consecutive hips treated with a tapered titanium stem system. J. Arthroplasty. 2010; 25 (1): 104-7.
  30. Greidanus N.V., Mitchell P.A., Masri B.A., Garbuz D.S., Duncan C.P. Principles of management and results of treating the fractured femur during and after total hip arthroplasty. Instr. Course Lect. 2003; 52: 309-22.
  31. Балберкин А.В., Ильин А.А., Мамонов А.М., Карпов В.Н., Колондаев А.Ф., Баранецкий А.Л. и др. Применение отечественных эндопротезов «СФЕН-Ц» и «ИЛЬЗА» у больных остеопорозом. Кремлевская медицина. 2007; 1: 67-9.
  32. Lewallen D.G., Berry D.J. Periprosthetic fractures associated with hip arthroplasty. In: Joint Replacement Arthroplasty. 3rd ed., Philadelphia, Pa: Churchill Livingstone; 2003: 902-19.
  33. Meek R.M.D., Norwood T., Smith R., Brenkel I.J., Howie C.R. The risk of peri-prosthetic fracture after primary and revision total hip and knee replacement. J. Bone Joint Surg. Br. 2011; 93 (1): 96-101.
  34. Streit M.R., Merle C., Clarius M., Aldinger P.R. Late peri-prosthetic femoral fracture as a major mode of failure in uncemented primary hip replacement. J. Bone Joint Surg. Br. 2011; 93 (2): 178-83.
  35. Berend K.R., Lombardi A.V. Jr. Intraoperative femur fracture is associated with stem and instrument design in primary total hip arthroplasty. Clin. Orthop. Relat. Res. 2010; 468 (9): 2377-81.
  36. Kold S., Mouzin O., Bourgeault C., Søballe K., Bechtold J.E. Femoral fracture risk in hip arthroplasty: smooth versus toothed instruments. Clin. Orthop. Relat. Res. 2003; 408: 180-8.
  37. Kold S., Rahbek O., Zippor B., Bechtold J.E., Søballe K. Bone compaction enhances fixation of hydroxyapatite-coated implants in a canine gap model. J. Biomed. Mater. Res. B. Appl. Biomater. 2005; 75 (1): 49-55.

Copyright (c) 2015 Eco-Vector



This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies