Extraosseous compression-dynamic osteosynthesis for the treatment of forearm bone fractures

Cover Page

Cite item

Full Text

Abstract

Special plate is suggested to provide extraosseous compression-dynamic osteosynthesis. The plate consists of two parts: base and rack. Longitudinal shift of the rack relative to the base is made by the rotation of the key which has a gear tenon on its end. The tenon and base are connected by gear transmission. Shift of the rack enables to put two bones fragments nearer and achieve their tightness and compression. Conditions for fracture healing are obtained.

About the authors

V. I. Zorya

Moscow Medical Dental Institute

Author for correspondence.
Email: info@eco-vector.com
Russian Federation, Moscow

V. M. Lirtsman

Moscow Medical Dental Institute

Email: info@eco-vector.com
Russian Federation, Moscow

A. V. Ulyanov

Moscow Medical Dental Institute

Email: info@eco-vector.com
Russian Federation, Moscow

References

  1. Абдуразаков У.А., Комкин В.Р., Батырханов Т.Т. // Съезд травматологов-ортопедов СНГ, 6-й: Материалы. —Ярославль, 1993. — С. 38.
  2. Анкин Л.Н., Анкин Н.Л. // Там же. — С. 40.
  3. Каплан А.В. Повреждения костей и суставов. — М., 1979.
  4. Мелнис А.Э., Кнетпс И.В. // Современные проблемы биомеханики. — Рига, 1985. — Вып. 2. — С. 38-69.
  5. Музыченко П.Ф. // Съезд травматологов-ортопедов СНГ, 6-й: Материалы. — Ярославль, 1993. — С. 88 - 89.
  6. Мюллер М.Ф. и др. Руководство по внутреннему остеосинтезу. — М., 1996. — С. 218.
  7. Рубленик И.М., Васюк В.Л. // Съезд травматологов- ортопедов СНГ, 6-й: Материалы. — Ярославль, 1993. — С. 97-98.
  8. Руцкий В.В., Артемьев А.А. // Ортопед. травматол. — 1989. — N 3. — С. 1-5.
  9. Тищенко В.П. // Съезд травматологов-ортопедов СНГ, 6-й: Материалы. — Ярославль, 1993. — С. 103.
  10. Lanyon L.E., Rubin С.Т. // J. Biomechanics. — 1984.— Vol. 17, N 12. — Р. 897-905.

Supplementary files

Supplementary Files
Action
1. JATS XML
2. Fig. 1. Scheme of an extraosseous compression-dynamic plate (explanations in the text).

Download (13KB)
3. Fig. 2. Radiographs of a patient with an oblique fracture of the radius and dislocation of the head of the ulna. a - before surgery; b — after external compression-dynamic osteosynthesis and reduction of the head of the ulna; c — 8 months after surgery: primary union of the fracture.

Download (71KB)

Copyright (c) 1999 Eco-Vector