Myoplasty by flaps with axial blood-supply in infectious complications after hip replacement

Cover Page

Cite item

Full Text

Abstract

After 359 total hip replacements (305 patients) infectious complications developed in 12 (3.3%) cases. Three cases were analyzed. To arrest the chronic inflammation, filling of residual cavities and substitute dermal defects muscular and myodermal flaps from m.tensor fasciae latae, m.rectus femoris and m. vastus lateralis with axial blood supply were used. Stopping of inflammatory process and radical closing of wound defect was achieved in all cases. In 2 patients it was possible to preserve stable to dislocation hip implants by means of wrapping up the implant neck with muscular flap.

About the authors

K. P. Pshenisnov

Yaroslavl State Medical Academy

Author for correspondence.
Email: info@eco-vector.com
Russian Federation, Yaroslavl

V. V. Danilyak

Yaroslavl State Medical Academy

Email: info@eco-vector.com
Russian Federation, Yaroslavl

V. V. Klyuchevskiy

Yaroslavl State Medical Academy

Email: info@eco-vector.com
Russian Federation, Yaroslavl

References

Supplementary files

Supplementary Files
Action
1. JATS XML
2. Fig. 1. Patient K.

Download (2MB)
3. Fig. 2. Patient G.

Download (2MB)

Copyright (c) 1998 Eco-Vector



This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies