Restoration of function in interphalangeal finger joints at injury sequelae by modified hinge-distraction device

Cover Page

Cite item

Full Text

Abstract

Seventy eight patients with sequelae of interphalangeal finger joint injuries ( long-standing dislocations, fracture-dislocations, peri- and intracapsular fractures, contractures) were treated by modified hinge-distraction devices. In 1-3 years follow up outcomes were evaluated in 71 patients. Good results were achieved in 68 cases (95.8%). Use of our hinge-distraction devices excluded the superfluous mobility, provided the main axis of articular ends motion, volume constancy of the articular split as well as the possibility of active and passive movements that gave adequate conditions for the restoration of osteoarticular structures as well as surrounding soft tissues.

About the authors

D. M. Zeitlin

Central Institute of Traumatology and Orthopedics. N.N. Priorov; Medical Unit No. 12

Author for correspondence.
Email: info@eco-vector.com
Russian Federation, Moscow; Samara

References

  1. Азолов В.В., Карева И.К., Малышев Л.В. //Ортопед. травматол. — 1981. — N 4. — С. 66-68.
  2. Гришин И.Г., Шинкаренко И.Н. //Сов. мед. — 1979. — N 3. — С. 34-38.
  3. Горячев А.Н., Тарасенко С.Ф., Пичугов М. //Дистракционный остеосинтез в клинике и эксперименте: Сб. науч. трудов. — Курган, 1988. — С. 30-34.
  4. Коршунов В.Ф. //Хирургия. — 1982. — N 3. — С. 119-120.
  5. Оганесян О.В., Шинкаренко И.Н., Абельцев В.П. Восстановление формы и функции кисти и пальцев с помощью аппаратов наружной чрескостной фиксации. — М., 1984.
  6. Ellis M.L. //Congress of European federation national assosiation of orthopaedics and traumatology, 2nd. — Munich, 1995. — P. 158.
  7. Pollak H.-J. //Z. Chir. — 1989. — Bd 114, N 6. — S. 40.
  8. Rosenberg L., Коп M. //J. Hand Surg. — 1986. — Vol. 11B, N 1. — P. 147-148.

Supplementary files

Supplementary Files
Action
1. JATS XML
2. Fig. 1. Articulating device of the apparatus for restoring the function of the interphalangeal joint.

Download (46KB)
3. Fig. 2. Elimination of contracture of the interphalangeal joint with the help of a hinge-distraction apparatus.

Download (56KB)

Copyright (c) 2022 Eco-Vector