Determination of Impurities in Magnesium Alloys by Inductively Coupled Plasma Mass Spectrometry


Цитировать

Полный текст

Открытый доступ Открытый доступ
Доступ закрыт Доступ предоставлен
Доступ закрыт Только для подписчиков

Аннотация

The methods of determination of Be, Cu, Fe, Ni, Si, Ti, and Cd in certified standard samples of magnesium alloys by inductively coupled plasma mass spectrometry (ICP-MS) are discussed. The procedure for dissolving the sample and preparing it for analysis is given. To eliminate spectral interference, a collision-reaction cell was used. An internal standard is selected and the accuracy characteristics of the magnesium alloy analysis method are calculated. The accuracy of the results is confirmed by analyzing a certified standard sample of magnesium alloy.