Three-Dimensional Screens for Measuring Non-Normalized Moments
- Autores: Arumov G.P.1, Bukharin A.V.1
-
Afiliações:
- Space Research Institute, Russian Academy of Sciences (IKI RAN)
- Edição: Volume 61, Nº 9 (2018)
- Páginas: 908-913
- Seção: Article
- URL: https://journals.rcsi.science/0543-1972/article/view/246595
- DOI: https://doi.org/10.1007/s11018-018-1523-1
- ID: 246595
Citar
Resumo
We describe a 3D screen design and a methodology for using such screens to determine scatterer-particle parameters, and propose a technique for the use of 3D screens in the measurement of non-normalized moments (up to 6th order). We show that the non-normalized moments can be determined from the attenuation in light power produced by a series of 3D screens; the number of screens determines the order of the moment to be measured. The non-normalized moments provide information on the equivalent cross-section of the scatterer particles and the distribution function of particles over cross-sectional area.