Ignition of the drops of coal–water fuel in a flow of air


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The ignition of the drops of coal–water fuel (CWF) in a high-temperature gas (air) flow was experimentally studied. The conditions and fundamental characteristics of the ignition (ignition delay times) were found. The effects of a number of factors (drop sizes and ambient temperatures) on the conditions of ignition were examined. Based on the results of experiments, a physical model was formulated for the processes of thermal preparation and ignition of CWF drops. The experimental delay times of the ignition of CWFs were compared with the theoretical values (obtained with the use of a previously developed mathematical model).

作者简介

A. Zakharevich

National Research Tomsk Polytechnic University

Email: bet@tpu.ru
俄罗斯联邦, pr. Lenina 30, Tomsk, 634050

V. Salomatov

Kutateladze Institute of Thermophysics, Siberian Branch

编辑信件的主要联系方式.
Email: bet@tpu.ru
俄罗斯联邦, Novosibirsk, 630090

P. Strizhak

National Research Tomsk Polytechnic University

Email: bet@tpu.ru
俄罗斯联邦, pr. Lenina 30, Tomsk, 634050

S. Syrodoi

National Research Tomsk Polytechnic University

Email: bet@tpu.ru
俄罗斯联邦, pr. Lenina 30, Tomsk, 634050

补充文件

附件文件
动作
1. JATS XML

版权所有 © Allerton Press, Inc., 2016