Influence of load increase rate during incremental test on aerobic performance indicators

Мұқаба

Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

Maximum oxygen consumption is an informative indicator of aerobic performance, and its assessment is associated with a significant investment of time. The paper compares the results of maximum tests with a stepwise increasing load with different duration of one load step: 15, 30, 60, 120 and 240 s. Maximum oxygen uptake, total operating time, and pair-wise relationship of protocols were assessed. There was no statistically significant difference in maximum oxygen uptake rate in protocols of different duration. Also, all the studied protocols showed a high correlation with each other (r = 0.92–0.97).

Толық мәтін

Рұқсат жабық

Авторлар туралы

V. Volkov

Russian University of Sports “GTSOLIFK”

Хат алмасуға жауапты Автор.
Email: fitclub@list.ru
Ресей, Moscow

R. Tambovtseva

Russian University of Sports “GTSOLIFK”

Email: fitclub@list.ru
Ресей, Moscow

V. Konyukhov

Russian University of Sports “GTSOLIFK”

Email: fitclub@list.ru
Ресей, Moscow

V. Markaryan

Russian University of Sports “GTSOLIFK”

Email: fitclub@list.ru
Ресей, Moscow

Әдебиет тізімі

  1. Lundby C., Montero D., Joyner M. Biology of VO2 max: looking under the physiology lamp // Acta Physiol. (Oxf). 2017. V. 220. № 2. P. 218.
  2. Borszcz F.K., Tramontin A.F., de Souza K.M. et al. Physiological correlations with short, medium, and long cycling time-trial performance // Res. Q. Exerc. Sport. 2018. V. 89. № 1. P. 120.
  3. Midgley A.W., Bentley D.J., Luttikholt H. et al. Challenging a dogma of exercise physiology: does an incremental exercise test for valid VO2max determination really need to last between 8 and 12 minutes? // Sports Med. 2008. V. 38. № 6. P. 441.
  4. ACSM’s guidelines for exercise testing and pre-scription / American College of Sports Medicine // Ed. Linda S. Pescatello. 9th ed., Wolters Kluwer/Lippincott Williams & Wilkins Health, 2013. P. 126.
  5. Adami A., Sivieri A., Moia C. et al. Effects of step duration in incremental ramp protocols on peak power and maximal oxygen consumption // Eur. J. Appl. Physiol. 2013. V. 113. № 10. P. 2647.
  6. Costa V.A.B., Midgley A.W., Carroll S. et al. Is a verification phase useful for confirming maximal oxygen uptake in apparently healthy adults? A systematic review and meta-analysis // PLoS One. 2021. V. 16. № 2. P. e0247057.
  7. Iannetta D., de Almeida Azevedo R., Ingram C.P. et al. Evaluating the suitability of supra-POpeak verification trials after ramp-incremental exercise to confirm the attainment of maximum O2 uptake // Am. J. Physiol. Regul. Integr. Comp. Physiol. 2020. V. 319. № 3. P. 315.
  8. Sawyer B.J., McMahon N., Thornhill K.L. et al. Supra-versus submaximal cycle ergometer verification of VO2max in males and females // Sports. 2020. V. 8. № 12. P. 163.
  9. Schaun G.Z. The maximal oxygen uptake verification phase: a light at the end of the tunnel? // Sports Med. Open. 2017. V. 3. № 1. P. 44.
  10. Scharhag-Rosenberger F., Carlsohn A., Lundby C. et al. Can more than one incremental cycling test be performed within one day? // Eur. J. Sport Sci. 2014. V. 14. № 5. P. 459.
  11. Hebisz P., Jastrzębska A.D., Hebisz R. Real assessment of maximum oxygen uptake as a verification after an incremental test versus without a test // Front. Physiol. 2021. V. 12. P. 739745.
  12. Riboli A., Rampichini S., Cè E. et al. Effect of ramp slope on different methods to determine lactate threshold in semi-professional soccer players // Res. Sports Med. 2019. V. 27. № 3. P. 326.
  13. Pierce S.J., Hahn A.G., Davie A., Lawton E.W. Prolonged incremental tests do not necessarily compromise VO2max in well-trained athletes // J. Sci. Med. Sport. 1999. V. 2. № 4. P. 356.
  14. Serresse O., Lortie G., Bouchard C., Boulay M.R. Estimation of the contribution of the various energy systems during maximal work of short duration // Int. J. Sports Med. 1988. V. 9. № 6. P. 456.
  15. Beneke R., Pollmann C., Bleif I. et al. How anaerobic is the Wingate Anaerobic Test for humans? // Eur. J. Appl. Physiol. 2002. V. 87. № 4-5. P. 388.
  16. Burnley M., Doust J.H., Vanhatalo A. A 3-min all-out test to determine peak oxygen uptake and the maximal steady state // Med. Sci. Sports Exerc. 2006. V. 38. № 11. P. 1995.
  17. Sperlich B., Haegele M., Thissen A. et al. Are peak oxygen uptake and power output at maximal lactate steady state obtained from a 3-min all-out cycle test? // Int. J. Sports Med. 2011. V. 32. № 6. P. 433.
  18. Volkov V.V., Tambovtseva R.V. [Сomparison of the rate of maximal oxygen consumption in the traditional step test and in the anaerobic wingate test] // Modern Issues of Biomedicine. 2023. V. 7. № 1. P. 37.
  19. Hermansen L., Saltin B. Oxygen uptake during maximal treadmill and bicycle exercise // J. Appl. Physiol. 1969. V. 26. № 1. P. 31.
  20. Volkov V.V., Tambovtseva R.V. [Maximum oxygen consumption and muscle mass working during the step test: a pilot study] // Modern Issues of Biomedicine. 2022. V. 6. № 4. P. 29.

Қосымша файлдар

Қосымша файлдар
Әрекет
1. JATS XML
2. Fig. 1. Range diagram for tests of different durations.

Жүктеу (79KB)
3. Fig. 2. Bland-Altman plot for tests with load stage durations of 15 and 120 s.

Жүктеу (79KB)
4. Fig. 3. The relationship between the maximum oxygen consumption (MOC) indicators obtained in the shortest and longest tests. Values ​​are presented in ml/min.

Жүктеу (65KB)
5. Fig. 4. The relationship between the maximum oxygen consumption (MOC) indicators obtained in the shortest and most “popular” tests. Values ​​are presented in ml/min.

Жүктеу (66KB)
6. Fig. 5. The relationship between the indicators of maximum oxygen consumption (MOC) obtained in protocols with a stage duration of 15 and 60 s. Values ​​are presented in ml/min.

Жүктеу (79KB)
7. Fig. 6. The relationship between the indicators of maximum oxygen consumption (MOC) obtained in protocols with a stage duration of 15 and 30 s. Values ​​are presented in ml/min.

Жүктеу (75KB)

© Russian Academy of Sciences, 2024

Осы сайт cookie-файлдарды пайдаланады

Біздің сайтты пайдалануды жалғастыра отырып, сіз сайттың дұрыс жұмыс істеуін қамтамасыз ететін cookie файлдарын өңдеуге келісім бересіз.< / br>< / br>cookie файлдары туралы< / a>