Approaches to Sample Preparation of Complex Biological Matrices for the Forensic Chemical Determination of Carfentanil

Мұқаба

Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

Two sample preparation procedures (liquid extraction into nonpolar solvent and solid-phase extraction) of cadaver biological tissues altered by putrefaction are compared. The work is devoted to the creation of a rapid and simple sample preparation method for the determination of carfentanil in putrefactive tissue samples. GC-MS analysis was performed on an Agilent 7820/5975 Maestro mass-selective chromatograph (Rxi-5ms, Restek). A three-quadrupole mass spectrometric detector (LC-MS/MS Shimadzu 8050) was used for HPLC-MS/MS analysis. Chromatographic separation was carried out on a column with reversed-phase sorbent Phenomenex Kinetex C18. Liver homogenates were chosen as the object of study, and alternatively, lysis products obtained by freezing/thawing of liver tissue samples. Sample preparation of homogenates was carried out by heptane liquid extraction and solid-phase extraction methods. Comparison of the results showed that liquids containing lysis products are the optimal choice for fast and efficient sample preparation. The analytical signal of target substances is 1.5-2 times higher than the signal obtained in the study of tissue homogenates using both solid-phase and liquid-phase extraction.

Авторлар туралы

M. Aigumov

Noyabrsk Psychoneurological Dispensary

Хат алмасуға жауапты Автор.
Email: aygumov.m@yandex.ru
Ресей, Noyabrsk

S. Savchuk

Association of Specialists in Chemical-toxicological and Forensic Chemical Analysis; The Institute of Physical Chemistry and Electrochemistry RAS (IPCE RAS)

Email: aygumov.m@yandex.ru
Ресей, St. Petersburg; Moscow

Әдебиет тізімі

  1. Leen J.L.S., Juurlink D.N. Carfentanil: A narrative review of its pharmacology and public health concerns // Can. J. Anaesth. 2019. V. 66. № 4. P. 414.
  2. Kreeger T.J., Arnemo J., Raath J.P. Handbook of Wildlife Chemical Immobilization, Int. Ed. Fort Collins: Wildlife Pharmaceuticals, 1999. С. 36.
  3. Stanley T. H., Egan T. D., Van Aken H. A Tribute to Dr. Paul A. J. Janssen: Entrepreneur Extraordinaire, Innovative Scientist, and Significant Contributor to Anesthesiology // Anesth. Analg. (Philadelphia, PA, U. S.). 2008. V. 106. № 2. P. 451.
  4. Lust E.B., Barthold C., Malesker M.A., Wichman T.O. Human health hazards of veterinary medications: Information for emergency departments // J. Emerg. Med. 2011. V. 40. № 2. P. 198.
  5. George A.V., Lu J.J., Pisano M.V., Metz J., Erickson T.B. Carfentanil – An ultra potent opioid // Am. J. Emerg. Med. 2010. V. 28. № 4. P. 530.
  6. Charlotte D., English L., Stewart C., Edgington M., Mcveigh J., Bellis M. Annual Report to the European Monitoring Centre for Drugs and Drug Addiction (EMCDDA) 2012 Edition. Liverpool: Liverpool John Moores University, 2013. С. 47.
  7. Мелентьев А. Б., Катаев С. С., Дворская О. Н. Дизайнерские наркотики. Метаболизм и подходы к анализу в биологических средах Москва: Изд-во “Перо”, 2016. 326 с.
  8. United Nations Office on Drugs and Crime “Recommended Methods for The Identification and Analysis of Fentanyl and Its Analogues in Biological Specimens, Manual for Use by National Drug Analysis Laboratories”. Vienna: United Nations, 2018. 69 c.
  9. Hikin L., Smith P.R., Ringland E., Hudson S., Morley S.R. Multiple fatalities in the North of England associated with synthetic fentanyl analogue exposure: Detection and quantitation a case series from early 2017// Forensic Sci. Int. 2018. V. 282. P. 179.
  10. Swanson D.M., Hair L.S., Strauch Rivers S.R., Smyth B.C., Brogan S.C., Ventoso A.D. et al. Fatalities involving carfentanil and furanyl fentanyl: Two case reports // J. Anal. Toxicol. 2017. V. 41. № 6. P. 498.
  11. Concheiro M., Chesser R., Pardi J., Cooper G. Postmortem toxicology of new synthetic opioids // Front. Pharmacol. 2018. V. 9. P. 1210.
  12. Shoff E.N., Zaney M.E., Kahl J.H., Hime G.W., Boland D.M. Qualitative identification of fentanyl analogs and other opioids in postmortem cases by UHPLC-ion trap-MSn // J. Anal. Toxicol. 2017. V. 41. № 6. P. 484.
  13. Marchei E., Pacifici R., Mannocchi G., Marinelli E., Busardò F.P., Pichini S. New synthetic opioids in biological and non-biological matrices: A review of current analytical methods // TrAC, Trends Anal. Chem. 2018. V. 102. P. 1.
  14. Wang L., Bernert J.T. Analysis of 13 fentanils, including sufentanil and carfentanil, in human urine by liquid chromatography-atmospheric-pressure ionization-tandem mass spectrometry// J. Anal. Toxicol. 2006. V. 30. № 5. P. 335.
  15. Shoff E.N., Zaney M.E., Kahl J.H., Hime G.W., Boland D.M. Qualitative identification of fentanyl analogs and other opioids in postmortem cases by UHPLC-ion trap-MSn// J. Anal. Toxicol. 2017. V. 41. № 6. P. 484.
  16. Sofalvi S., Schueler H.E., Lavins E.S., Kaspar C.K., Brooker I.T., Mazzola C.D. et al. An LC–MS-MS method for the analysis of carfentanil, 3-methylfentanyl, 2-furanyl fentanyl, acetyl fentanyl, fentanyl and norfentanyl in postmortem and impaired-driving cases // J. Anal. Toxicol. 2017. V. 41. № 6. P. 473.
  17. Papsun D., Isenschmid D., Logan B.K. Observed carfentanil concentrations in 355 blood specimens from forensic investigations // J. Anal. Toxicol. 2017. V. 41. № 9. P. 777.
  18. Савчук С.А., Григорьев А.М. Судебно-химическое исследование волос, ногтевых срезов, крови, мочи, органов и тканей трупа на наличие психоактивных веществ, включая метаболиты/маркеры синтетических каннабимиметиков методом газовой хроматографии с масс-селективным детектированием. Москва: РЦСМЭ МЗ РФ, 2019. 42 с.

Қосымша файлдар

Қосымша файлдар
Әрекет
1. JATS XML

© Russian Academy of Sciences, 2025

Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».