Skin ultrasound examination in the cosmetologists practice


Cite item

Full Text

Abstract

The article presents the study results for available options as well as diagnostics value and limitations related to
skin ultrasound scans in medical cosmetology. The authors applied the skin ultrasound scanning method at 22 MHz
and 75 MHz to visualize the structure of epidermis, derma and subcutaneous cellular tissue. Patients with chronic
inflammatory dermatoses, skin neoplasms, cicatrical changes and age-related skin changes made a part of the sample
under examination. The authors obtained scanograms of the skin structure and used them to measure the depth of
different skin layers and formations as well as tissue echodensity. The qualitative and quantitative data were applied to
specify the clinical diagnosis and assess the treatment efficacy.

About the authors

A P Bezuglyy

ФГУ «Российский научный центр восстановительной медицины и курортологии»Минздравсоцразвития

Email: arturbezugly@gmail.com
ведущий научный сотрудник лаборатории аппаратной физиотерапиик. м.н; ФГУ «Российский научный центр восстановительной медицины и курортологии»Минздравсоцразвития

N N Bikbulatova

клиника «АНТА-Мед»

клиника «АНТА-Мед»

E A Shuginina

ЗАО «Косметологическая лечебница Институт красоты»

ЗАО «Косметологическая лечебница Институт красоты»

P A Belkov

клиника «АНТА-Мед»

клиника «АНТА-Мед»

N R Khabutdinova

клиника «АНТА-Мед»

клиника «АНТА-Мед»

A P Bezuglyi

N N Bikbulatova

Ye A Shuginina

P A Belkov

N R Khabutdinova

References

  1. Vogt M., Kaspar K., Altmeyer P. et. al. High frequency ultrasound for high resolution skin imaging. Frequenz 2005; 59: 5-6: 150-153.
  2. Jasaitiene D., Valiukeviciene S., Linkeviciute G. et al. Principles of high-frequency ultrasonography for investigation of skin pathology. J Eur Acad Dermatol Venerol, 2011; 25: 4: 375-382.
  3. Vogt M., Scharenberg R., Moussa G. et al. A New High Frequency Ultrasound Skin Imaging System: Imaging Properties and Clinical in Vivo Results. Acoustical Imaging 2007; 28: 137-144.
  4. Kaspar K., Vogt M., Ermert H. et al. 100-MHz-Sonographie zur Darstellung des Stratum corneum an der Palmarhaut nach Anwendung verschiedener Externa. Ultraschall in der Medizin 1999; 3: 20: 110-114.
  5. Vogt M., Paul B., Scharenberg S. et al. Analysis and measurement of spectral characteristics and spatial resolution of high frequency ultrasound imaging systems. Proc, IEEE US Symposium 2004; 2137-2140.
  6. Ахмедова Л.Е., Безуглый А.П. Новые технологии в диагностике - ультразвуковое исследование кожи. Вестн. восстан. мед. 2005; 4: 32-34.
  7. Gniadecka M. Effects of ageing on dermal echogenicity. Skin Res Technol 2001; 7: 204-207.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2011 Bezuglyy A.P., Bikbulatova N.N., Shuginina E.A., Belkov P.A., Khabutdinova N.R., Bezuglyi A.P., Bikbulatova N.N., Shuginina Y.A., Belkov P.A., Khabutdinova N.R.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

Согласие на обработку персональных данных

 

Используя сайт https://journals.rcsi.science, я (далее – «Пользователь» или «Субъект персональных данных») даю согласие на обработку персональных данных на этом сайте (текст Согласия) и на обработку персональных данных с помощью сервиса «Яндекс.Метрика» (текст Согласия).