Computational–Experimental Verification of Technologies of Utilization of the Concentrate Formed in the Reverse-Osmosis Water Demineralization Cycle


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

Technologies for utilizing the wastewater of the reverse-osmosis plants (ROPs) to prepare the make-up water for power-generating plants of combined heat and power plants and nuclear power plants are proposed and substantiated using mathematical models and full-scale experiments. The ROPs use natural feedwater with a wide range of quality characteristics. For the first time, variants of the treatment of the concentrate formed in the ROP cycle have been proposed for the reuse of the latter by acidifying it in H-type cation- exchange filters charged with a weakly acidic cation-exchange resin. By admixing part of the filtrate processed in the H-type cation-exchange filters to the feedwater, the latter is acidified thus reducing the probability of formation of carbonaceous sediments and water consumption. The rest of the filtrate subjected to a conversion process is used as a constituent of the make-up feedwater of the heating system or potable water, which eliminates the discharge of the reverse-osmosis plant wastewater into the environment. Another feature of the proposed technology is that the H-type cation-exchange filters are integrated into a regenerant solution reuse circuit (RSRC). As a result, the consumption rate of sulfuric acid for regeneration equals the stoichiometric rate and the regeneration yields gypsum used to produce a binding agent for construction. The kinetics of separation of gypsum from the spent regenerant solutions with different chemical compositions was studied experimentally as applied to the RSRC conditions. The procedure of operating filters charged with the Lewatit CNP-LF cation-exchange resin was trialed under production conditions. It was established that the height of the filtering cation-exchange resin layer should be 1.0–1.5 m and the concentration of the regenerant solution should not exceed 0.8% at a rate of 10–15 m/h. The basic components of the technological scheme were trialed under production conditions on a water treatment plant in service.

Sobre autores

E. Yurchevskii

AO OKB GIDROPRESS

Autor responsável pela correspondência
Email: aquachim@yandex.ru
Rússia, Podol’sk, Moscow oblast, 142193

V. Solodyannikov

OOO SVT-Engineering

Email: aquachim@yandex.ru
Rússia, Samara, 443080


Declaração de direitos autorais © Pleiades Publishing, Inc., 2018

Este site utiliza cookies

Ao continuar usando nosso site, você concorda com o procedimento de cookies que mantêm o site funcionando normalmente.

Informação sobre cookies