Investigation of Technical and Economic Viability of the 450-MW CCGT Unit’s Operation in the GTU Based CHP Mode
- Authors: Arakelyan E.K.1, Andryushin A.V.1, Burtsev S.Y.2, Andryushin K.A.1
-
Affiliations:
- National Research University Moscow Power Engineering Institute (NRU MPEI)
- All-Russian Scientific Research Institute for Physical-Engineering and Radiotechnical Metrology (VNIIFTRI), pos. Mendeleevo
- Issue: Vol 65, No 12 (2018)
- Pages: 900-910
- Section: Steam Turbine, Gas Turbine, and Combined-Cycle Power Plants and Their Auxiliary Equipment
- URL: https://journals.rcsi.science/0040-6015/article/view/173115
- DOI: https://doi.org/10.1134/S0040601518120017
- ID: 173115
Cite item
Abstract
Technical viability and economic feasibility of improving the technology of a 450-MW CCGT unit’s participation in power load leveling of the power system operating in a GTU based CHP mode by transferring a 450-MW CCGT T-125/150 steam turbine to the driving mode instead of its shutdown are considered. It is shown that the shutdown of the steam turbine is associated with increased fuel consumption under start-up conditions, delayed steam turbine loading and the CCGT unit as a whole, and a loss of steam turbine life characteristics. The technology of transferring the 450-MW CCGT unit to the GTU based CHP mode, possible schemes of high- and low-pressure steam distributions between line water heaters, and methods and results of calculation of power parameters of the 450-MW CCGT unit with the turbine shutdown and transferring it to the driving mode in the absence and presence of peak-load heaters in the heat balance are presented. It is shown that switching the 450-MW CCGT unit from the base 290 MW electric load and 1006 GJ/h heat production to the GTU based CHP mode leads to a decrease in electric capacity of the CCGT unit by 90 MW and an increase in heat production by 335–348 GJ/h. Comparative graphs of the steam turbine start-up and the CCGT unit rated loading in the comparable variants after its operation in the GTU based CHP mode for 8–10 h are given. Evaluation techniques and results of the economic efficiency of the generator driving mode are compared with the shutdown of the steam turbine. Based on the performed calculations, it is shown that, for various combinations of fuel equivalent and electricity costs and heating tariffs, the expedient time for switching the steam turbine to the driving mode is 10–18 h. Additional advantages of the driving mode are noted, such as improvement of the steam turbine reliability due to the elimination of cyclic temperature variations of its steam-inlet elements and vibrational oscillations in the final stages of the low-pressure cylinder and the possibility of the steam turbine generator to operate as a synchronous condenser.
About the authors
E. K. Arakelyan
National Research University Moscow Power Engineering Institute (NRU MPEI)
Author for correspondence.
Email: Edik_arakelyan@inbox.ru
Russian Federation, Moscow, 111250
A. V. Andryushin
National Research University Moscow Power Engineering Institute (NRU MPEI)
Email: Edik_arakelyan@inbox.ru
Russian Federation, Moscow, 111250
S. Yu. Burtsev
All-Russian Scientific Research Institute for Physical-Engineering and Radiotechnical Metrology (VNIIFTRI), pos. Mendeleevo
Email: Edik_arakelyan@inbox.ru
Russian Federation, Solnechnogorskii raion, Moscow oblast, 141570
K. A. Andryushin
National Research University Moscow Power Engineering Institute (NRU MPEI)
Email: Edik_arakelyan@inbox.ru
Russian Federation, Moscow, 111250