From palpation of the pulse to cuff-free methods: evolution of arterial pressure measurement methods
- Authors: Solnceva T.D.1, Sivakova O.A.1, Chazova I.E.1
-
Affiliations:
- Myasnikov Institute of Clinical Cardiology, National Medical Research Center for Cardiology
- Issue: Vol 93, No 4 (2021)
- Pages: 526-531
- Section: History of medicine
- URL: https://journals.rcsi.science/0040-3660/article/view/71281
- DOI: https://doi.org/10.26442/00403660.2021.04.200690
- ID: 71281
Cite item
Full Text
Abstract
The arterial pressure is an important physiological indicator. The review describes the different techniques of measurement of arterial pressure, their advantages and limitations. Moreover, it also represents a historical reference about the main stage of the development of clinical sphygmomanometrya that nowadays is a relevant method for measuring arterial pressure. The emergence and the development of devices for daily monitoring of arterial pressure and modern techniques for non-invasive arterial pressure measurement are described too.
Full Text
##article.viewOnOriginalSite##About the authors
Tatiana D. Solnceva
Myasnikov Institute of Clinical Cardiology, National Medical Research Center for Cardiology
Author for correspondence.
Email: tatanasolnceva372@gmail.com
ORCID iD: 0000-0002-7381-7818
клин. ординатор отд. гипертонии
Russian Federation, MoscowOlga A. Sivakova
Myasnikov Institute of Clinical Cardiology, National Medical Research Center for Cardiology
Email: tatanasolnceva372@gmail.com
ORCID iD: 0000-0002-0060-095X
к.м.н., зав. отд-нием артериальной гипертонии
Russian Federation, MoscowIrina E. Chazova
Myasnikov Institute of Clinical Cardiology, National Medical Research Center for Cardiology
Email: tatanasolnceva372@gmail.com
ORCID iD: 0000-0002-9822-4357
акад. РАН, д.м.н., проф., зам. ген. дир. ФГБУ «НМИЦ кардиологии» по научно-экспертной работе, рук. отд. гипертонии ИКК им. А.Л. Мясникова
Russian Federation, MoscowReferences
- World Health Organization. A global brief on hypertension. Silent killer, global public health crisis. World Health Day 2013. Geneva, World Health Organization, 2013. Available at: https://www.who.int/cardiovascular_diseases/publications/global_brief_hypertension/en/
- Lewis WH. The evolution of clinical sphygmomanometry. Bull N Y Acad Med. 1941;17(11):871-81.
- Saklayen MG, Deshpande NV. Timeline of History of Hypertension Treatment. Front Cardiovasc Med. 2016;3(3). doi: 10.3389/fcvm.2016.00003
- Androutsos G, Karamanou M. William Harvey (1578–1657): discoverer of Blood Circulation. Hellenic J Cardiol. 2012; 53(1):6-9.
- Booth J. A short history of blood pressure measurement. Proc R Soc Med. 1977;70(11):793-799.
- Болезни сердца и сосудов. Под. ред. Е.И. Чазова. М.: Медицина, 1992 [Diseases of the heart and blood vessels. Ed. EI Chazov. Moscow: Meditsina, 1992 (In Russ.)].
- Ludwig C. Beiträge zur Kenntnis des Einflusses der Respirations-bewegungen auf den Blutlauf im Aortensysteme. Arch J Anat Physiol: wiss Med. 1847; p. 242-302.
- Potain C. Du sphygmomanometre et de la mesure de la pression arterielle chez I homme. Arch. de physiol.norm et patch.1889;1:556.
- Riva-Rocci S. Un nuovo sfigmomanometro. Gazetta Medical di Torino. 1896; 47: 1001.
- Руководство по артериальной гипертонии. Под ред. Е.И. Чазова, И.Е. Чазовой. Медиа Медика, 2005 [A guide to arterial hypertension. Ed. EI Chazov, IE Chasova. Media Medika, 2005 (In Russ.)].
- Коротков Н.С. К вопросу о методах исследования кровяного давления. Известия императорской Военно-медицинской академии Санкт-Петербурга. 1905;4(11):365-7 [Korotkov NS. K voprosu o metodakh issledovaniya krovyanogo davleniya. Izv. imperatorskoi Voenno-meditsinskoi akademii Sankt-Peterburga. 1905;4(11):365-7 (In Russ.)].
- Попов C.Е. Петербургский доктор Н.С. Коротков – основоположник новой эпохи в развитии мировой медицины. Артериальная гипертензия. 2005;2(11):71-4 [Popov CE. Petersburg doctor N.S. Korotkov is the founder of a new era in the development of world medicine. Arterial’naya gipertenziya. 2005;2(11):71-4 (In Russ.)].
- Mancia G. Clinical use of ambulatory blood pressure. Am J Hypertens. 1989;2:505-45. doi: 10.1093/ajh/2.2.50S
- Hill L, Barnard S. A simple and accurate form of sphygmometer or arterial pressure gauge contrived for clinical use. Br Med J. 1897;2:904. doi: 10.1136/bmj.2.1918.904
- Kain HK, Hinman AT, Sokolow M. Arterial blood pressure messureaments with a portable recoder in hypertensive patients. Circulation. 1964;30:882-92. doi: 10.1161/01.cir.30.6.882
- Рогоза А.Н., Ощепкова Е.В., Цагареишвили Е.В. Современные неинвазивные методы измерения артериального давления для диагностики артериальной гипертонии и оценки эффективности лечения. Атмосфера. Новости кардиологии. 2008;1:2-4 [Rogoza AN, Oshchepkova EV, Tsagareishvili EV. Modern non-invasive methods of measuring blood pressure for the diagnosis of arterial hypertension and assessment of the effectiveness of treatment. Atmosfera. Novosti kardiologii. 2008;1:2-4 (In Russ.)].
- Hinman AT, Engel BT, Bickford AF. Portable blood pressure recoder: accurancy and preliminary use in evaluating intra-daily variations in pressure. Am Heart J. 1962;63:663-8. doi: 10.1016/0002-8703(62)90011-x
- Kim-Gau NG. Survey of Automated Noninvasive Blood Pressure Monitors. J Clin Eng. 1994;19(6):452-63. doi: 10.1097/00004669-199411000-00014
- Montfrans V. Oscillometric blood pressure measurement: progress and problems. Blood Press Monit. 2001;6:287-90. doi: 10.1097/00126097-200112000-00004
- O’Brien E, Atkins N. State- of- the- market from the dableducational. Blood Press Monit. 2007;12:377-9. doi: 10.1097/MBP.0b013e328244de94
- Arakawa T. Recent Research and Developing Trends of Wearable Sensors for Detecting Blood Pressure. Sensors. 2018;18:2772. doi: 10.3390/s18092772
- Kuwabara M. Validation of a wrist-type home nocturnal blood pressure monitor in the sitting and supine position according to the ANSI/AAMI/ISO81060-2:2013 guidelines: Omron HEM-9601T. J Clin Hypertens (Greenwich). 2020;22(6):970-8. doi: 10.1111/jch.13864
- Kario K. Management of Hypertension in the Digital Era: Small Wearable Monitoring Devices for Remote Blood Pressure Monitoring. Hypertension. 2020;76(3):640-50. doi: 10.1161/HYPERTENSIONAHA.120.14742.
- Kawai N, Ogasawara T, Nakashima H. Development of functional textile “Hitoe”:Wearable electrodes for monitoring human vital signals. IEICE Communications Society Magazine. 2017;11:17-23. doi: 10.1587/bplus.11.17
- Nishizawa M, Hoshide S, Okawara Y. Strict blood pressure control achieved using an ICT-based home blood pressure monitoring system in a catastrophically damaged area after a disaster. J Clin Hypertens (Greenwich). 2017;1:26-9. doi: 10.1111/jch.12864
- Kanegae H, Suzuki K, Ito T. Highly precise risk prediction model for new-onset hypertension using artificial intelligence techniques. The Journal of Clinical Hypertension. 2020; 22: 445-450. doi: 10.1111/jch.13759