Comparison of the Operating Conditions of Electric Arc Furnaces with Short and Long Arc Discharges
- Авторлар: Cherednichenko V.S.1, Bikeev R.A.1, Zuev S.P.1
-
Мекемелер:
- Novosibirsk State Technical University
- Шығарылым: Том 2019, № 12 (2019)
- Беттер: 1259-1263
- Бөлім: Metallurgical and Electrothermal Equipment
- URL: https://journals.rcsi.science/0036-0295/article/view/173740
- DOI: https://doi.org/10.1134/S0036029519120073
- ID: 173740
Дәйексөз келтіру
Аннотация
A mathematical model is developed to describe the electromagnetic energy transfer between the phases of an electric arc furnace. This model is used to study the efficiency of operation of a DSP-100 electric arc furnace with the coplanar arrangement of a secondary current lead for short, medium, and long arc discharges. The energy processes in the furnace are found to be determined by both the potential gradients in arc discharges and the electromagnetic coupling of the phases, which causes redistribution of the total power released in arc discharges between the phases. Recommendations for the application of a phase-by-phase controlled reactor during long-arc operation are made.