Improvement of the thermal operating conditions of steel-teeming ladles


Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

The thermal state of a 30-t steel-teeming ladle is subjected to CFD simulation. The results obtained are verified by direct measurements of the lining and steel temperatures at various stages of technology under the conditions of an operating electric-furnace shop in a miniplant. The simulation results are used to determine the quantitative indices of the effect of the lining heating temperature on the energy consumed in steelmaking. It is shown that an increase in the temperature of the 30-t ladle lining by 100°C leads to a decrease in the temperature of metal tapping from EAF by ~11°C, which is equivalent to a saving of 4 kWh electric power per 1 t liquid steel.

Авторлар туралы

M. Krasnyanskii

VNIIMETMASh

Email: ylkats@gmail.com
Ресей, Ryazanskii pr. 8A, Moscow, 109428

Ya. Kats

VNIIMETMASh

Хат алмасуға жауапты Автор.
Email: ylkats@gmail.com
Ресей, Ryazanskii pr. 8A, Moscow, 109428