Improved method for determining the stress relaxation at the crack tip
- Authors: Grinevich A.V.1, Erasov V.S.1, Avtaev V.V.1
-
Affiliations:
- All-Russia Institute of Aviation Materials VIAM
- Issue: Vol 2017, No 10 (2017)
- Pages: 901-904
- Section: Diagnostics and Mechanical Test Techniques
- URL: https://journals.rcsi.science/0036-0295/article/view/171804
- DOI: https://doi.org/10.1134/S0036029517100081
- ID: 171804
Cite item
Abstract
A technique is suggested to determine the stress relaxation at the crack tip during tests of a specimen of a new type at a constant crack opening fixed by a stay bolt. The shape and geometry of the specimen make it possible to set the load and to determine the crack closure force after long-term exposure using the force transducer of a tensile-testing machine. The stress relaxation at the crack tip is determined in a V95pchT2 alloy specimen at elevated temperatures.
Keywords
About the authors
A. V. Grinevich
All-Russia Institute of Aviation Materials VIAM
Author for correspondence.
Email: viam660@yandex.ru
Russian Federation, ul. Radio 17, Moscow, 105005
V. S. Erasov
All-Russia Institute of Aviation Materials VIAM
Email: viam660@yandex.ru
Russian Federation, ul. Radio 17, Moscow, 105005
V. V. Avtaev
All-Russia Institute of Aviation Materials VIAM
Email: viam660@yandex.ru
Russian Federation, ul. Radio 17, Moscow, 105005