Analysis of the accuracy of the inverse problem solution for a differential heterodyne microscope as applied to rectangular plasmonic waveguides


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The existence, uniqueness, and stability of the inverse problem solution for a scanning differential heterodyne microscope as applied to rectangular plasmonic waveguides have been analyzed. The consideration is based on an algorithm using a trial-and-error method that we proposed previously to characterize plasmonic waveguides with a triangular profile. The error of the inverse problem (IP) solution is calculated as dependent on the initial data and with allowance for their errors. Instability domains are found for the IP solution, where the solution error sharply increases. It is shown that the instability domains can be eliminated and the accuracy of the IP solution can be significantly improved in the entire range of initial data by taking initial data in the form of two phase responses of the microscope at different wavelengths.

作者简介

I. Akhmedzhanov

Prokhorov General Physics Institute

Email: zolotov@kapella.gpi.ru
俄罗斯联邦, ul. Vavilova 38, Moscow, 119991

D. Baranov

Prokhorov General Physics Institute

Email: zolotov@kapella.gpi.ru
俄罗斯联邦, ul. Vavilova 38, Moscow, 119991

E. Zolotov

Prokhorov General Physics Institute

编辑信件的主要联系方式.
Email: zolotov@kapella.gpi.ru
俄罗斯联邦, ul. Vavilova 38, Moscow, 119991

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2016