On the Flammability Limit
- Authors: Zamashchikov V.V.1,2
-
Affiliations:
- Voevodsky Institute of Chemical Kinetics and Combustion, Siberian Branch
- Novosibirsk State University
- Issue: Vol 54, No 4 (2018)
- Pages: 393-397
- Section: Article
- URL: https://journals.rcsi.science/0010-5082/article/view/153169
- DOI: https://doi.org/10.1134/S0010508218040020
- ID: 153169
Cite item
Abstract
The upper flammability limit of ethane–air and ethane–oxygen mixtures was determined experimentally for various initial temperatures and pressures. In the experiments, the upper flammability limit increased with increasing initial temperature and pressure, which is consistent with literature data. The limit was determined in a closed vessel with central ignition. The obtained limit corresponds to the quenching of the flame propagating downward after its rise under the action of the Archimedes force.
About the authors
V. V. Zamashchikov
Voevodsky Institute of Chemical Kinetics and Combustion, Siberian Branch; Novosibirsk State University
Author for correspondence.
Email: albor@kinetics.nsc.ru
Russian Federation, Novosibirsk, 630090; Novosibirsk, 630090
Supplementary files