State of Gas in a Piston Compressor at the Start of Compression
- Authors: Shatalov I.K.1, Antinov Y.A.1, Smirnov S.V.1, Mamaev V.K.1, Ramazanov É.R.1, Shkarin K.V.1
-
Affiliations:
- Russian People’s Friendship University
- Issue: Vol 54, No 11-12 (2019)
- Pages: 835-841
- Section: Article
- URL: https://journals.rcsi.science/0009-2355/article/view/236430
- DOI: https://doi.org/10.1007/s10556-019-00559-z
- ID: 236430
Cite item
Abstract
Calculation formulas for estimating the influence of the state parameters of temperature, pressure, and moisture content on the operation of a piston compressor are obtained. It is shown that at the start of compression in a compressor temperature depends mainly on heating of the gas produced by the walls and its moisture content. The pressure at the start of compression depends on the speed of the piston and the moisture content of the gas. The principal factors responsible for a reduction of the feed rate and efficiency of the compressor are the increase in temperature and the decrease in pressure at the start of compression.
About the authors
I. K. Shatalov
Russian People’s Friendship University
Author for correspondence.
Email: rudn-tit@yandex.ru
Russian Federation, Moscow
Yu. A. Antinov
Russian People’s Friendship University
Email: rudn-tit@yandex.ru
Russian Federation, Moscow
S. V. Smirnov
Russian People’s Friendship University
Email: rudn-tit@yandex.ru
Russian Federation, Moscow
V. K. Mamaev
Russian People’s Friendship University
Email: rudn-tit@yandex.ru
Russian Federation, Moscow
É. R. Ramazanov
Russian People’s Friendship University
Email: rudn-tit@yandex.ru
Russian Federation, Moscow
K. V. Shkarin
Russian People’s Friendship University
Email: rudn-tit@yandex.ru
Russian Federation, Moscow
Supplementary files