Analysis of Thermodynamic Efficiency of Small-Scale Natural Gas Liquefying Plant Operating on Medium-Pressure Cycle


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The sole Russian Federation LNG plant operating in Ekaterinburg on medium-pressure expander cycle (Claude cycle) allows utilization of the energy of pressure fall at a gas distributing station. The thermodynamic efficiency of the plant is 17.5%, which matches the current level of development in this category of cryogenic plants. Statistical entropy analysis showed that the major contribution to the nonequilibrity of the liquefaction process is made by remote mainline compressor (up to 40%) and turboexpander-compressor aggregate (up to 25%). This fact opens up possibilities of improving LNG plants further by switching to other methods of cold generation using, in particular, rotor wave cryogenerator

作者简介

A. Arkharov

Bauman Moscow State Technical University

Email: v.semyonov1959@gmail.com
俄罗斯联邦, Moscow

V. Semenov

Bauman Moscow State Technical University

编辑信件的主要联系方式.
Email: v.semyonov1959@gmail.com
俄罗斯联邦, Moscow

补充文件

附件文件
动作
1. JATS XML

版权所有 © Springer Science+Business Media New York, 2016