Experimental Study of Distance between Evaporator and Condensate of Inclined Multistage Desalination Plant


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

An experimentally designed and researched inclined multistage laboratory pilot desalination plant is installed so as to run with the highest productivity at a distance of four to eight centimeters between the evaporator and the condensate, especially at 5.21 cm. The evaporator’s unit sizes are chosen according to the calculation procedure proposed by the authors of this article.