Experimental Study of Distance between Evaporator and Condensate of Inclined Multistage Desalination Plant
- Авторлар: Mirzaev M.S.1, Samiev K.A.1, Mirzaev S.M.1
-
Мекемелер:
- Bukhara State University
- Шығарылым: Том 55, № 1 (2019)
- Беттер: 36-40
- Бөлім: Solar Plants and Their Application
- URL: https://journals.rcsi.science/0003-701X/article/view/149597
- DOI: https://doi.org/10.3103/S0003701X19010109
- ID: 149597
Дәйексөз келтіру
Аннотация
An experimentally designed and researched inclined multistage laboratory pilot desalination plant is installed so as to run with the highest productivity at a distance of four to eight centimeters between the evaporator and the condensate, especially at 5.21 cm. The evaporator’s unit sizes are chosen according to the calculation procedure proposed by the authors of this article.