The continuing application of cardiac implantable electronic devices (CIED) has led to an increasing concern regarding disturbances in the tricuspid valve (TV). The most prevalent TV issue related to lead implantation is tricuspid regurgitation. CIED-induced tricuspid regurgitation is associated with emerging or worsening preexisting heart failure and increased mortality rate. Because discontinuing the implantation of these instruments is not feasible, further knowledge of their mechanical problems may lead to advancements. This review addresses the available data regarding CIED-induced tricuspid regurgitation, elucidating its plausible pathomechanisms, diagnostic methods, and prospective treatments.
Full Text
##article.viewOnOriginalSite##About the authors
Rana Zhafira Amanda
Airan Raya Hospital
Email: ranazhaf@gmail.com
ORCID iD: 0000-0002-8686-1834
MD; General Practitioner Airan Raya Hospital
Indonesia, South LampungSidhi Laksono Purwowiyoto
Faculty Of Medicine, Universitas Muhammadiyah Prof Dr Hamka
Author for correspondence.
Email: sidhilaksono@uhamka.ac.id
ORCID iD: 0000-0002-2959-8937
MD, CPHM, Lecturer; Department of Cardiology, Faculty of Medicine, Prof Dr Hamka Muhammadiyah University
Indonesia, TangerangReferences
- Gelves-Meza J, Lang RM, Valderrama-Achury MD, et al. Tricuspid regurgitation related to cardiac implantable electronic devices: an integrative review. J Am Soc Echocardiogr. 2022;35(11):1107–1122. doi: 10.1016/j.echo.2022.08.004
- Offen S, Strange G, Playford D, et al. Prevalence and prognostic impact of tricuspid regurgitation in patients with cardiac implantable electronic devices: From the national echocardiography database of Australia. Int J Cardiol. 2023;370:338–344. doi: 10.1016/j.ijcard.2022.10.160
- Husain A, Raja FT, Fatallah A, et al. Tricuspid stenosis: An emerging disease in cardiac implantable electronic devices era. Case report and literature review. J Cardiol Cases. 2017;15(6):190–193. doi: 10.1016/j.jccase.2017.02.003
- Addetia K, Harb SC, Hahn RT, et al. Cardiac implantable electronic device lead-induced tricuspid regurgitation. JACC Cardiovasc Imaging. 2019;12(4):622–636. doi: 10.1016/j.jcmg.2018.09.028
- Nakajima H, Seo Y, Ishizu T, et al. Features of lead-induced tricuspid regurgitation in patients with heart failure events after cardiac implantation of electronic devices – A three-dimensional echocardiographic study. Circ J. 2020;84(12):2302–2311. doi: 10.1253/circj.CJ-20-0620
- Zhang XX, Wei M, Xiang R, et al. Incidence, risk factors, and prognosis of tricuspid regurgitation after cardiac implantable electronic device implantation: a systematic review and meta-analysis. J Cardiothorac Vasc Anesth. 2022;36(6):1741–1755. doi: 10.1053/j.jvca.2021.06.025
- Seo Y, Nakajima H, Ishizu T, et al. Comparison of outcomes in patients with heart failure with versus without lead-induced tricuspid regurgitation after cardiac implantable electronic devices implantations. Am J Cardiol. 2020;130:85–93. doi: 10.1016/j.amjcard.2020.05.039
- Andreas M, Burri H, Praz F, et al. Tricuspid valve disease and cardiac implantable electronic devices. Eur Heart J. 2024;45(5): 346–365. doi: 10.1093/eurheartj/ehad783
- Chodór-Rozwadowska KE, Sawicka M, Morawski S, et al. Lead-related tricuspid regurgitation and ventricle dysfunction: Current management and future perspectives. Adv Clin Exp Med. 2023;32(9):1049–1061. doi: 10.17219/acem/159531
- Carino D, Sala A, Zancanaro E, et al. Surgical treatment of tricuspid valve regurgitation in patients with cardiac implantable electronic devices: long-term results. Eur J Cardiothoracic Surg. 2022;62(3):ezac239. doi: 10.1093/ejcts/ezac239
- Stankovic I, Voigt JU, Burri H, et al. Imaging in patients with cardiovascular implantable electronic devices: part 2—imaging after device implantation. A clinical consensus statement of the European Association of Cardiovascular Imaging (EACVI) and the European Heart Rhythm Association (EHRA) of the ESC. Eur Heart J Cardiovasc Imaging. 2023.25(1).e33–e54. doi: 10.1093/ehjci/jead273
- Javed N, Iqbal R, Malik J, et al. Tricuspid insufficiency after cardiac-implantable electronic device placement. J Community Hosp Intern Med Perspect. 2021;11(6):793–798. doi: 10.1080/20009666.2021.1967569
- Alnaimat S, Doyle M, Krishnan K, Biederman RWW. Worsening tricuspid regurgitation associated with permanent pacemaker and implantable cardioverter-defibrillator implantation: A systematic review and meta-analysis of more than 66,000 subjects. Heart Rhythm. 2023.20(11):1491–1501. doi: 10.1016/j.hrthm.2023.07.064
- Papageorgiou N, Falconer D, Wyeth N, et al. Effect of tricuspid regurgitation and right ventricular dysfunction on long-term mortality in patients undergoing cardiac devices implantation: >10-year follow-up study. Int J Cardiol. 2020;319:52–56. doi: 10.1016/j.ijcard.2020.05.062
- Kanawati J, Ng ACC, Khan H, et al. Long-term follow-up of mortality and heart failure hospitalisation in patients with intracardiac device-related tricuspid regurgitation. Heart Lung Circ. 2021;30(5):692–697. doi: 10.1016/j.hlc.2020.08.028
- Safiriyu I, Mehta A, Adefuye M, et al. Incidence and prognostic implications of cardiac-implantable device-associated tricuspid regurgitation: a meta-analysis and meta-regression analysis. Am J Cardiol. 2023;209:203–211. doi: 10.1016/j.amjcard.2023.09.064
- Van De Heyning CM, Elbarasi E, Masiero S, et al. Prospective study of tricuspid regurgitation associated with permanent leads after cardiac rhythm device implantation. Can J Cardiol. 2019;35(4): 389–395. doi: 10.1016/j.cjca.2018.11.014
- Arabi P, Özer N, Ateş AH, et al. Effects of pacemaker and implantable cardioverter defibrillator electrodes on tricuspid regurgitation and right sided heart functions. Cardiol J. 2015;22(6):637–644. doi: 10.5603/CJ.a2015.0060
- Guigui S, Zedan A, LaPietra A, et al. Cardiovascular implantable electronic device-related tricuspid regurgitation: A multidisciplinary team approach. J Thorac Dis. 2020;12(5):2986–2989. doi: 10.21037/jtd.2020.01.64
- Ehra A, Task A, Members F, et al. 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy Developed by the Task Force on cardiac pacing and cardiac resynchronization therapy of the European Society of Cardiology ( ESC ) With the special contribution of the European Heart Rhythm. 2021;1–94. doi: https://academic.oup.com/eurheartj/article/42/35/3427/6358547?login=false
- Vahanian A, Beyersdorf F, Praz F, et al. 2021 ESC/EACTS Guidelines for the management of valvular heart disease: Developed by the Task Force for the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Rev Esp Cardiol (Engl Ed). 2022;75(6):524. doi: 10.1016/j.rec.2022.05.006
- Lurz J, Rommel KP, Unterhuber M, et al. Safety and efficacy of transcatheter edge-to-edge repair of the tricuspid valve in patients with cardiac implantable electronic device leads. JACC Cardiovasc Interv. 2019;12(20):2114–2116. doi: 10.1016/j.jcin.2019.05.034
Supplementary files