Corrosion resistance improvement of 30XGCN2A steel by ion implantation using cathodes based on immiscible components


Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

Research results of the corrosion resistance of 30XGCN2A steel after irradiation by a polyion beam using an implanter of copper, lead, monotectic alloy of 64% Cu–36% Pb (MA), and MA + Sn and MA + Al alloys as a cathode are given. An increase in the corrosion resistance of implanted samples during a total corrosion test carried out in a salt-spray chamber, as well as an increase in the electrode potential threshold value of the pitting corrosion when using an implanter of MA + Sn and MA + Al alloys as a cathode, is observed.