Determination of the Life Cycle of Heat-Exchange Tubes of Vapor Condensers on the Basis of Statistical Analysis of Local Pitting Corrosion According to Data of Eddy Current Testing
- 作者: Golovin V.A.1, Pechnikov N.V.2, Shchelkov V.A.1, Tsivadze A.Y.1
-
隶属关系:
- Frumkin Institute of Physical Chemistry and Electrochemistry, Russian Academy of Sciences
- NPO ROKOR LLC
- 期: 卷 54, 编号 6 (2018)
- 页面: 1221-1232
- 栏目: Investigation Methods for Physicochemical Systems
- URL: https://journals.rcsi.science/2070-2051/article/view/204663
- DOI: https://doi.org/10.1134/S2070205118060138
- ID: 204663
如何引用文章
详细
The possibility is shown of creating a chart of local corrosion damage in the walls of heat-exchange tubes on the basis of the data of matrix eddy current testing with registration of the position, type, and depth of all local corrosion damage areas. The results of examination of condensers operated under different conditions and at different plants are used to calculate the theoretical depth distribution of defects. It is shown that, in all cases, a satisfactory statistical description of the corrosion defect depth on the cooling water size is obtained by employing the Weibull distribution. Pearson’s coefficient is in the range of 0.994–0.997.
作者简介
V. Golovin
Frumkin Institute of Physical Chemistry and Electrochemistry, Russian Academy of Sciences
编辑信件的主要联系方式.
Email: golovin@rocor.ru
俄罗斯联邦, Moscow, 119071
N. Pechnikov
NPO ROKOR LLC
Email: golovin@rocor.ru
俄罗斯联邦, Moscow, 129110
V. Shchelkov
Frumkin Institute of Physical Chemistry and Electrochemistry, Russian Academy of Sciences
Email: golovin@rocor.ru
俄罗斯联邦, Moscow, 119071
A. Tsivadze
Frumkin Institute of Physical Chemistry and Electrochemistry, Russian Academy of Sciences
Email: golovin@rocor.ru
俄罗斯联邦, Moscow, 119071
补充文件