This article is devoted to experimental studies of the operational capability of an electric pump unit in operation with new and worn out rotor wheels. Results of measurements are presented for the operating parameters of the electric pump unit, vibration monitoring, and thermal imaging, and the calculation of static durability of a shaft, based on which the main conclusions are formulated.