Studying the Dependence of the Life of Convection Superheaters of the Number of Damaged Coils


Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

The life of a high-pressure convection superheater with damaged coils and a low-pressure superheater of the second stage of a TGMP-314 boiler is analyzed numerically. The dependence of the temperatures of steam, metal, and flue gas at the outlet of the coil banks on the number of plugged coils is established. It is shown that plugging gives rise to sparse banks with overheated coils, high-temperature gas plume that initiates overheating of the downstream tube banks, nonuniform softening of the metal, and reduction of the operational reliability of the superheaters.

Авторлар туралы

V. Bogachev

JSC “All-Russia Thermal Engineering Institute” (VTI)

Хат алмасуға жауапты Автор.
Email: bogachev_vti@rambler.ru
Ресей, Moscow

T. Pshechenkova

JSC “All-Russia Thermal Engineering Institute” (VTI)

Email: bogachev_vti@rambler.ru
Ресей, Moscow