Detection of Carbon Monoxide in Humid Air with Double-Layer Structures Based on Semiconducting Metal Oxides and Silicalite

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Double-layer structures based on gas-sensitive semiconducting metal oxides and silicalite-1 were tested in detection of carbon monoxide in humid air. Pure tin dioxide and that modified with antimony and palladium served as materials of the sensitive layer. Upon deposition of a silicalite-1 layer on SnO2 and SnO2/PdOx, the signal for CO in dry air at room measurement temperature (T = 25°C) grows, but an increase in the air humidity results in that the sensor sensitivity fully disappears. Raising the measurement temperature to 100°C makes weaker the adverse effect of the humidity. The double-layer structure containing the SnO2(Sb)/PdOx nanocomposite is characterized by the most stable sensor signal that is independent of the air humidity within the range RH = 4‒65%.

作者简介

D. Gulevich

Lomonosov Moscow State University

Email: roum@inorg.chem.msu.ru
俄罗斯联邦, Moscow, 119991

A. Marikutsa

Lomonosov Moscow State University

Email: roum@inorg.chem.msu.ru
俄罗斯联邦, Moscow, 119991

M. Rumyantseva

Lomonosov Moscow State University

编辑信件的主要联系方式.
Email: roum@inorg.chem.msu.ru
俄罗斯联邦, Moscow, 119991

P. Fabrichnyi

Lomonosov Moscow State University

Email: roum@inorg.chem.msu.ru
俄罗斯联邦, Moscow, 119991

T. Shatalova

Lomonosov Moscow State University

Email: roum@inorg.chem.msu.ru
俄罗斯联邦, Moscow, 119991

A. Gas’kov

Lomonosov Moscow State University

Email: roum@inorg.chem.msu.ru
俄罗斯联邦, Moscow, 119991

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2018