Effect of the degradation of ion-exchange resins on the quality of high-purity water prepared by ion-exchange deionization


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

In the course of water deionization on ion-exchange filters of mixed action, charged with a mixture of KU-2×8 ch.s. cation exchanger and AV-17×8 ch.s. anion exchanger, which are ion-exchange resins of nuclear class, the water being treated is contaminated with soluble organic substances originating from degradation of the resins. Their concentration can reach 20 µg L–1, gradually decreasing to 5–6 µg L–1. Procedures were suggested for determining soluble organic substances washed out from the ion-exchange filters, including gravimetric determination of their sum in aqueous extracts from the organic ion exchangers, spectrophotometric determination in water being purified on the ion exchangers, and preconcentration of electrically charged forms of soluble organic substances by electroosmosis.

作者简介

L. Moskvin

St. Petersburg State University

编辑信件的主要联系方式.
Email: moskvinln@yandex.ru
俄罗斯联邦, Universitetskaya nab. 7–9, St. Petersburg, 199034

V. Rakov

Aleksandrov Research Institute of Technology

Email: moskvinln@yandex.ru
俄罗斯联邦, Koporskoe sh. 72, Sosnovyi Bor, Leningradskaya oblast, 188540

N. Yakimova

St. Petersburg State University

Email: moskvinln@yandex.ru
俄罗斯联邦, Universitetskaya nab. 7–9, St. Petersburg, 199034

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2016