Stability of Corona Discharge in High Pressure Nitrogen
- Авторы: Andrei Bologa 1
-
Учреждения:
- Karlsruhe Institute of Technology
- Выпуск: Том 55, № 5 (2019)
- Страницы: 548-555
- Раздел: Article
- URL: https://journals.rcsi.science/1068-3755/article/view/231341
- DOI: https://doi.org/10.3103/S1068375519050028
- ID: 231341
Цитировать
Аннотация
The study of corona discharge is important for successful development of various electrostatic technologies. The current study is directed at investigating the stability of a negative polarity direct current corona discharge in high pressure nitrogen. Experiments were carried out at test set-up equipped with a high temperature high pressure (HTHP) corona discharge ionizer which has star-shaped disk high voltage electrodes installed inside of a cylinder grounded electrode. The “direct” and “indirect” current–voltage characteristics (CVCs) were measured for various gas pressure values without and with a gas flow through the HTHP set-up casing and without external heating of the ionizer grounded electrode. An increase of gas pressure results in an increase of a “CVC-direct” onset voltage and in a decrease of the corona current at a constant value of the applied voltage. A hysteresis effect is observed for the corona discharge CVCs at a high gas pressure when corona currents for the “CVC-indirect” are measured at voltages lower than the “CVC-direct” onset voltage. The area of the “hysteresis window” increases with an increase of gas pressure.
Ключевые слова
Об авторах
Andrei Bologa
Karlsruhe Institute of Technology
Автор, ответственный за переписку.
Email: andrei.bologa@kit.edu
Германия, Eggenstein-Leopoldshafen, 76344
Дополнительные файлы