Use of Direct Optical Heterodyning for Measuring Hardness by the Leeb Method
- Авторлар: Kazieva T.1, Gubskii K.1, Kuznetsov A.1, Glukhov R.1
-
Мекемелер:
- National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)
- Шығарылым: Том 45, № 10 (2019)
- Беттер: 967-969
- Бөлім: Article
- URL: https://journals.rcsi.science/1063-7850/article/view/208440
- DOI: https://doi.org/10.1134/S1063785019100109
- ID: 208440
Дәйексөз келтіру
Аннотация
In this paper, we describe a portable system for measuring the indenter velocity in hardness meters implemented according to the Leeb method. The developed system is a fiber interferometer, in which a radiation source is a semiconductor laser with a wavelength of 1550 nm. The presented experimental results confirm the ability of the system to measure indenter velocities with an uncertainty of 0.001 m/s, which satisfies the requirements of the standards for this method of measuring hardness.