Measurements of the Plasma Parameters in a Mirror Trap by Means of Laser-Induced Fluorescence
- Авторы: Kutuzov D.S.1, Moskalenko I.V.1, Bragin E.Y.1, Zhil’tsov V.A.1, Yanchenkov S.V.1
-
Учреждения:
- National Research Center “Kurchatov Institute,”
- Выпуск: Том 44, № 9 (2018)
- Страницы: 791-798
- Раздел: Plasma Diagnostics
- URL: https://journals.rcsi.science/1063-780X/article/view/186920
- DOI: https://doi.org/10.1134/S1063780X18090076
- ID: 186920
Цитировать
Аннотация
Results of measurements of the absolute density of ArII ions in a mirror trap with a toroidal divertor are presented. The ion density was measured by the method of laser-induced fluorescence with the use of ArII metastable states. A technique is proposed to estimate the plasma electron temperature from the ratio of the fluorescence signals obtained by comparing the intensities of different optical transitions of ArII.