Modification of SXB Method for Hydrogen in ITER Main Chamber


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

A modification of the SXB method, used for evaluating the atom/ion flux from the tokamak first wall into plasma using the observed wavelength-integrated spectral line intensity, is proposed. The modification allows, using the high-resolution spectroscopy data, to estimate — in real time measurements — the fluxes of atomic and molecular hydrogen from the first wall of the tokamak main chamber into plasma without measurements of molecular spectra. The modified SXB method is tested by comparing the results with the SOLPS code simulations for six modelled types of the SOL plasma profiles in ITER. The proposed modification is motivated by the fact that the hydrogen molecular spectra will not be used for ITER operation diagnostics because of difficulties of their interpretation.

作者简介

R. Khusnutdinov

National Research Center “Kurchatov Institute”; National Research Nuclear University MEPhI (Moscow Engineering Physics Instutute)

编辑信件的主要联系方式.
Email: hatach@mail.ru
俄罗斯联邦, Moscow, 123098; Moscow, 115409

A. Kukushkin

National Research Center “Kurchatov Institute”; National Research Nuclear University MEPhI (Moscow Engineering Physics Instutute)

Email: hatach@mail.ru
俄罗斯联邦, Moscow, 123098; Moscow, 115409

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2019