Photomultiplier-Based Scintillation Radiation Detectors of Increased Sensitivity and Time Resolution for Measurements under Conditions of High Electromagnetic Interference


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Scintillation detectors for detecting X-ray, gamma, and neutron radiation with time resolutions of 3–4 ns and having high noise stability have been developed. The detector housings are shielded from the strong electromagnetic interference produced at the moment of discharge. The detector design features an original voltage divider. With these detectors, the parameters of the high-energy radiation from a megavolt atmospheric nanosecond discharge can be studied at the limit of sensitivity of this class of devices.

作者简介

A. Rodionov

Lebedev Physical Institute; Moscow Institute of Physics and Technology (State University)

编辑信件的主要联系方式.
Email: ra1231@gmail.com
俄罗斯联邦, Moscow, 119991; Dolgoprudny, Moscow oblast, 141701

A. Oginov

Lebedev Physical Institute

Email: ra1231@gmail.com
俄罗斯联邦, Moscow, 119991

K. Shpakov

Lebedev Physical Institute

Email: ra1231@gmail.com
俄罗斯联邦, Moscow, 119991

补充文件

附件文件
动作
1. JATS XML

版权所有 © Allerton Press, Inc., 2018