A procedure has been developed to detect surface defects in the head and foot of a rail using a magnetic method involving thin-film magnetoresistive field sensors. The setup consists of a system for moving the rail in the longitudinal direction, a magnetizing solenoid, cartridges with field sensors for inspecting the rail head and foot, a DC electromagnet with attached pole pieces, and a “robotic” transverse movement unit with an additional cartridge for revealing long-sized defects (over the entire length of the rail). The electrical signals of the sensors are transmitted to an analog-to-digital converter and processed digitally. The possibility of detecting all surface defects stipulated by the regulatory and technical documentation of JSC Russian Railways is demonstrated.
作者简介
A. Shleenkov
Mikheev Institute of Metal Physics, Ural Branch, Russian Academy of Sciences
编辑信件的主要联系方式.
Email: shleenkov@imp.uran.ru
俄罗斯联邦, Yekaterinburg, 620108
O. Bulychev
Mikheev Institute of Metal Physics, Ural Branch, Russian Academy of Sciences
Email: shleenkov@imp.uran.ru
俄罗斯联邦, Yekaterinburg, 620108
A. Pastukhov
Mikheev Institute of Metal Physics, Ural Branch, Russian Academy of Sciences
Email: shleenkov@imp.uran.ru
俄罗斯联邦, Yekaterinburg, 620108
S. Shleenkov
Mikheev Institute of Metal Physics, Ural Branch, Russian Academy of Sciences
Email: shleenkov@imp.uran.ru
俄罗斯联邦, Yekaterinburg, 620108
补充文件