Acoustic-emission location of flaws during multiple-run welding of contours with complex shapes


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

A modified tabular method for locating acoustic-emission signals, which is intended for determining the coordinates of flaws when inspecting a multiple-run welding process with a lower error rate, and the result of using this method for determining the coordinates of flaws when welding a circular contour using a piezoelectric antenna, which consists of four acoustic-emission transducers, are considered. It is shown experimentally that the application of the modified tabular method allowed an increase in the accuracy of determining the coordinates of introduced flaws when using the acoustic-emission testing method.

作者简介

L. Stepanova

Chaplygin Siberian Research Institute of Aviation

编辑信件的主要联系方式.
Email: stepanova@stu.ru
俄罗斯联邦, ul. Polzunova 21, Novosibirsk, 630051

I. Ramazanov

Chaplygin Siberian Research Institute of Aviation

Email: stepanova@stu.ru
俄罗斯联邦, ul. Polzunova 21, Novosibirsk, 630051

V. Kireenko

SEVMASH Production Association

Email: stepanova@stu.ru
俄罗斯联邦, Severodvinsk


版权所有 © Pleiades Publishing, Ltd., 2016
##common.cookie##