Two approaches to the solution of problems of ultrasonic flaw metering: Analysis of a high-quality image of reflectors and correlation analysis of measured echo signals


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The problem of ultrasonic flaw metering consists in the obtainment of information on the reflector type, its dimensions, and the coordinates of its location. As the accuracy of determining the parameters of a discontinuity increases, the results of ultrasonic testing become more reliable. A highquality image of reflectors, which is reconstructed using the C-SAFT method with consideration for multiple reflections of pulses from the boundaries of a test object that makes it possible to determine the types and dimensions of reflectors, can be considered as one of the tools of flaw metering. However, the C-SAFT method disregards the features of reflections from discontinuities with nonuniform scattering indicatrices. As a development of flaw-metering methods, it is proposed to determine the parameters of a discontinuity from the results of comparison of the measured echo signals and estimated echo signals, which are calculated as functions of the discontinuity parameters. The results of using the proposed methods of ultrasonic flaw metering in numerical and model experiments, which demonstrate the working capacity of the proposed approach, are presented.

作者简介

E. Bazulin

EChO+ Scientific and Production Center

编辑信件的主要联系方式.
Email: bazulin@echoplus.ru
俄罗斯联邦, ul. Tvardovskogo 8, Technopark Strogino, Moscow, 123458

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2016